AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 103 of 256 
15.07.2002 
Command 
Behaviour on channel 1 
Differences on channel 2+3 
ATS8 
1
as described 
not usable 
ATS10 
1
as described 
not usable 
ATS18 
1
as described 
not usable 
AT\Q<n> 
as described 
not usable 
ATZ 
as described 
data call parameters not changed 
 
1
)
  Siemens GSM engines support the registers S0 - S29. You can change S0, S3, S4, S5, S6, S7,S8, 
S10 and S18 using the related ATSn commands (see starting from pg. 32).  
2)
  MC35 allows to use the GPRS commands on all logical channels, but to remain compatible to fu-
ture releases it is recommended to use them on channel 1 only. PDP contexts can be defined on 
any channel, but  are visible and usable only on the channel on which they are defined (thus it is 
not possible to define a context on channel 2 and activate it on channel 3). GPRS data calls can be 
initiated on any channel but will be always established on channel 1. 
3)
  The applicability of the +++ escape sequence depends on the customer’s external application 
based on the Mulitplexer Protocol. Recommendations for implementing an appropriate modem 
status command (MSC) are provided in [5], Chapter “Escape Sequence”. The demo program PC 
MUX uses +++ as described in Chapter 2.2.  
 
Table 9:  Summary of AT commands with different behaviour in Multiplex mode 
Command 
Description 
Chapter 
AT\Q<n> 
It is recommended to use hardware flow control (AT\Q3). XON/XOFF 
flow control (AT\Q1) is not supported in Multiplex mode 
ATH 
Terminates any voice, fax or CSD call in progress, no matter what 
channel was used to enter ATH. 
Terminates GPRS connections or clears active PDP context if issued 
on the same channel. 
AT&V 
Different default configurations on channels 1, 2 and 3 
AT+IPR 
Before you start Multiplex mode, it is recommended to set the ME to 
57600 bps. For GPRS we suggest to use 115200 bps . 
The bit rate cannot be changed while Multiplex mode is active, there-
fore do not use AT+IPR=<rate> in this mode. 
AT+IPR=0 
Autobauding is not compatible with Multiplex mode. It is neither pos-
sible to start MUX when autobauding is active, nor to set autobauding 
during Multiplex mode. 
AT+CALA 
Alarm calls can be separately configured on each channel. The read 
command returns the total number of alarm calls activated on all 
channels. 
AT+CMEE 
Presentation mode can be separately configured for each channel. 
AT+CNMA 
If Multiplex mode is activated the +CNMI parameter will be set to zero 
on all channels, if one channel fails to acknowledge an incoming 
message within the required time. 
AT+CNMI 
Phase 2+ parameters can only be used on one channel. The parame-
ter for <mt> and <ds> on the other channels have to be set to zero. If 
either a SM or a Status Report is not acknowledged, all +CNMI pa-
rameter will be set to zero on all channels.