AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 191 of 256 
15.07.2002 
 
Read command 
AT^SBC? 
 
Response 
^SBC: <bcs>,<bcl>,<mpc> 
<bcs
Connection status of battery pack 
<bcl> Battery 
charge 
level 
 
While charging is in progress (charging adapter connected) the 
battery capacity is not available. Consequently, parameter <bcl>=0. 
To query the battery capacity disconnect the charger. 
<mpc> 
Average power consumption 
 <mpc> 
is obtained from the ME's power consumption, plus the value 
you have specified for the application by using the write command 
AT^SBC=<current>. Remember that the ME's power consumption 
varies with its operating mode (IDLE, TALK, DATA, GPRS/DATA) 
and the power level.  
 If 
<current> was not yet specified and no battery pack NTC is 
detected  <mpc> returns only the module's present power 
consumption. 
 If 
<current> was not yet specified, but the NTC of the connected 
battery pack is detected, an offset value of 200mA will, by default, be 
added. 200mA is an estimated value which represents the power 
consumption of a typical external application. Drawn from practical 
experience it serves as a precaution to ensure proper charging in 
case you have not entered <current>. It is strongly recommended 
that you enter the correct power consumption of your application as 
described below. 
 
Note: If the battery does not incorporate an NTC, or the battery and 
the NTC are not compliant with the requirements specified in [1], the 
battery cannot be detected by the ME.  
 
Write command 
AT^SBC= 
<current> 
 
 
Use the write command to specify the power consumption of your external appli-
cation. This information enables the ME to calculate the average power consump-
tion <mpc> and to properly control the charging process. If the value is not correct 
the entire charging process may be affected. Resulting problems may be wrong 
responses to the AT^SBC read command, overcharging, or the battery does not 
reach full capacity. 
 
The write command registers the serial port as the output channel for unsolicited 
result codes related to charging. 
 
When the ME is powered down or reset, the value of <current> is restored to its 
default. This affects the charging control and disables the presentation of unsolic-
ited result codes. Therefore, the parameter should be set every time when 
needed after rebooting the ME. 
 
Response 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
 
Parameter 
<current>  Enter the current consumption of your application in mA (0...5000). If 
used, the current provided over the by 2.9V VDD pin of the ZIF inter-
face (maximum 70mA) must be added, too.