Table 12: Operating modes of the ME indicated by status LED (if <mode> = 1
):
LED mode
Function
Off
MC35 module: ME is off or running in SLEEP, Alarm or
Charge-only mode.
MC35 Terminal: ME is off or in SLEEP mode.
Charge-only mode.
MC35 Terminal: ME is off or in SLEEP mode.
600 ms On / 600ms Off
No SIM card inserted or no PIN entered, or network
search in progress, or ongoing user authentication, or
network login in progress.
search in progress, or ongoing user authentication, or
network login in progress.
75 ms On / 3 s Off
Logged to network (monitoring control channels and user
interactions). No call in progress.
interactions). No call in progress.
75 ms on / 75 ms Off / 75 ms On / 3 s Off One or more GPRS contexts activated.
Flashing
Indicates GPRS data transfer: When a GPRS transfer is in
progress, the LED goes on within 1 second after data
packets were exchanged. Flash duration is approximately
0.5 s.
progress, the LED goes on within 1 second after data
packets were exchanged. Flash duration is approximately
0.5 s.
On
Depending on type of call:
Voice call: Connected to remote party.
Data call: Connected to remote party or exchange of pa-
rameters while setting up or disconnecting a call.
Voice call: Connected to remote party.
Data call: Connected to remote party or exchange of pa-
rameters while setting up or disconnecting a call.