Parameter 
<time>  string type value; format is "yy/MM/dd,hh:mm:ss", where characters 
indicate year (two last digits), month, day, hour, minutes. E.g. 6
th
 of 
May 2001, 22:10:00 hours equals to “01/05/06,22:10:00" (see also 
+CCLK). Note: if <time> equals current date and time or is to an ear-
lier date, TA returns +CME ERROR: <21>. 
 
<n> 
integer type value indicating the array index of the alarm. Index starts 
with 0. If only this value is returned by the test command, it is default 
and indicates that only one alarm time is possible; however, if a sec-
ond alarm time is set, the previous alarm is deleted. 
 
<type>  integer type value indicating the type of the alarm 
0  Alarm indication: text message via serial interface 
 
<text> 
string type value indicating the text to be displayed when alarm time 
is reached; maximum length is <tlength>. After first connection to 
power supply <text> is undefined. 
Note:
 <text> will be stored to the non-volatile flash memory when the 
device enters the Power Down mode via AT^SMSO (pg. 202). Once 
saved, it will be available upon next power-up, until you overwrite it by 
typing another text. This eliminates the need to enter the full string 
when setting a fresh alarm and thus, saves memory due to the limited 
number of flash memory write cycles (e.g. 100.000).  
 
<tlength> integer type value indicating the maximum length of <text>. The 
maximum length is 16. 
Unsolicited result code 
 
Indicates reminder call: 
+CALA: <text> 
 
Indicates ME wake-up into Alarm mode: 
^SYSSTART ALARM MODE 
+CALA: <text> 
If autobauding is active (AT+IPR=0) the URCs ^SYSSTART ALARM MODE 
and +CALA: <text> do not appear. Therefore, avoid using Alarm mode in con-
junction with autobauding. 
 
Reference 
GSM 07.07 
Note 
·  <text> should not contain characters which are coded differently in ASCII 
and GSM (e.g. Ä, Ö, Ü), see also Chapter 9.5. 
·  In the event of power outage the GSM engine retains the current alarm set-
ting, but the RTC will be reset to <time> = “00/01/01,00:00:00” and must be 
restored after resume of power (see also AT+CCLK, pg. 73. It is only in 
Power Down mode, that the RTC is kept powered from a dedicated voltage 
regulator, thus saving the current date and time. 
·  When the GSM engine wakes up to Alarm mode, the system takes 1s to re-
initialize the RTC and to update the current time. Therefore, it is recom-
mended to wait 1s before using the AT+CCLK command (for example 1s af-
ter ^SYSSTART has been output).  
·  Please consider when using multiplex mode (+CMUX, pg. 101)
It is possible to use +CALA with every logical channel (1 – 3). 
The total no. of possible alarm events is shared by all channels. If <n> = 
0 is returned by the test command, this indicates that only one common 
alarm time is possible for all logical channels.