SAFETY PRECAUTIONS
CAUTION
:  Do  not  attempt  to  modify  this  product  in  any  way.  Unau-
thorized modifications will not only void the warranty, but may lead to your
being liable for any resulting property damage or user injury.
Service  work  should  be  performed  only  after  you  are  thoroughly  familiar
with  all  of  the  following  safety    checks  and  servicing  guide-lines.  To  do
otherwise, increases the risk of potential hazards and injury to the user.
SAFETY CHECKS
After the original service problem has been corrected, a check should be
made of the following:
SUBJECT : FIRE & SHOCK HAZARD
1. Be  sure  that  all  components  are  positioned  in  such  a  way  as  to  avoid
possibility of adjacent component shorts. This is especially important on
those chassis which are transported to and from the repair shop.
2. Never release a repair unless all protective devices such as insula-tors,
barriers,  covers,  shields,  strain  reliefs,  and  other  hardware  have  been
reinstalled per original design.
3. Soldering  must  be  inspected  to  discover  possible  cold  solder  joints,
frayed leads, damaged insulation (including A.C. cord), solder splashes
or sharp solder points. Be certain to remove all loose for-eign particals.
4. Check  for  physical  evidence  of  damage  or  deterioration  to  parts  and
components, and replace if necessary follow original layout, lead length
and dress.
5. No  leads  or  components  should  touch  a  receiving  tube  or  a  resistor
rated at 1 watt or more. Lead tension around protruding metal sur-faces
must be avoided.
6. All critical components such as fuses, flameproof resistors, capaci-tors,
etc. must be replaced with exact factory types. Do not use replacement
components other than those specified or make unrecommended circuit
modifications.
7. After re-assembly of the set always perform an A.C. leakage test on all
exposed  metallic  parts  of  the  cabinet,  (the  channel  selector  knob,
antenna  terminals,  handle  and  screws)  to  be  sure  the  set  is  safe  to
operate  without  danger  of  electrical  shock.  Do  not  use  a  line  isolation
transformer during this test. Use an A.C. voltmeter, having 5000 ohms
per  volt  or  more  sensitivity,  in  the  following  manner  :  connect  a  1500
ohm 10 watt resistor, paralleled by a 15 mfd. 150V A.C. type capacitor
between  a  known  good  earth  ground  (9water  pipe,  conduit,  etc.)  and
the  exposed  metallic  parts,  one  at  a  time.  Measure  the  A.C.  voltage
across the combination of 1500 ohm resistor and 0.15 MFD capacitor.
Reverse the A.C. plug and repeat A.C. voltage measurements for each
exposed  metallic  part.  Voltage  measured  must  not  exceed  0.75  volts
R.M.S. This corresponds to 0.5 milliamp A.C. Any value exceeding this
limit constitutes a potential shock hazard and must be corrected imme-
diately.
The  lightning  flash  with  arrowhead  symbol,
within an equilateral triangle, is intended to alert
the service personnel to the presence of uninsu-
lated  dangerous  voltage   that  may  be  of  suffi-
cienty  magnitude  to  constitute  a  risk  of  electric
shock.
The  exclamation  point  within  an  equilateral  tri-
angle  is  intended  to  alert  the  service  personnel
to  the  presence  of  important  safety  information
in service literature.
Fuse  symbol  is  printed  on  pcb  adjacent  to  the
fuse, with  RISK OF FIRE REPLACE FUSE AS
MARKED .  The  symbol  is  explained  in  the  ser-
vice manual with the following wording or equiv-
alent. 
CAUTION
:  FOR  CONTINUED  PROTECTION  AGAINST  FIRE
HAZARD,  REPLACE  ONLY  WITH  SAME  TYPE  (4A,  125V)   and
ATTENTION
:  AFIN  D ASSU  UNE  PROTECTION  PERMANENTE
CONTRE LES RISQUES D INCENDIE, REMPLACER UNIQUE-MENT
PAR UN FUSIBLE DE MEME TYPE ET DE  4A, 125V .
SUBJECT : X-RADIATION
1. Be  sure  procedures  and  instructions  to  all  service  personnel  cover
the  subject  of  X-rays  in  current  T.V.  receivers  is  the  picture  tube.
However, this tube does not emit X-rays when the high voltage is at
the  factory  specified  level.  The  proper  value  is  given  in  the  appli-
cable  schematic.  Operation  at  higher  voltages  may  cause  a  failure
of  the  picture  tube  or  high  voltage  supply  and,  under  certain  cir-
cumstances, may produce radiation in excess of desirable levels.
2. Only  factory  specified  C.R.T.  anode  connectors  must  be  used.
Degaussing shields also serve as X-ray shield in color sets. Always
re-install them.
3. It  is  essential  that  the  serviceman  has  available  an  accurate  and
reliable  high  voltage  meter.  The  calibration  of  the  meter  should  be
checked  perio  -  dically  against  a  reference  standard.  Such  as  the
one available at your distributor.
4. When  the  high  voltage  circuitry  is  operating  properly  there  is  no
possibility  of  an  X-radiation  problem.  Every  time  a  color  chassis  is
serviced, the brightness should be run up and down while monitor-
ing the high voltage with a meter to be certain that the high voltage
does  not  exceed  the  specified  value  and  that  it  is  regulating    cor-
rectly.  We  suggest  that  you  and  your  service  organization  review
test  procedures  so  that  voltage  regulation  is  always  checked  as  a
standard servicing procedure. And that the high voltage reading be
recorded on each customer s invoice.
5. When troubleshooting and making test measurements in a receiver
with a problem of excessive high voltage, avoid being unnecessarily
close to the picture tub eand the high voltage compartment. Do not
operate the chassis longer than is necessary to locate the cause of
excessive voltage.
6. Refer to HV, B+and Shutdown adjustment procedures described in
the appropriate schematic and diagrams(where used).
10WATT
GOOD EARTH GROUND
SUCH AS THE WATER
PIPE, CONDUIT, ETC.
1500       OHM
A.C. VOLTMETER
PLACE THIS PROBE
ON EACH EXPOSED
METAL PART
0.15 uF