Справочник Пользователя для Siemens micromaster 411

Скачать
Страница из 164
10  Engineering Information 
Issue 03/01 
 
MICROMASTER 411 & COMBIMASTER 411    Operating Instructions  
142 
6SE6400-5CA00-0BP0  
Table 10-5 
BiCo Connections (r0055 to r1119) 
 
 
 
 
COBO 
COBO 
CO 
CO 
CO 
COBO 
COBO 
CO 
CO 
CO 
CO 
CO 
CO 
CO 
P
a
rN
BiCo
 
 
 
005
5
 
005
6
 
006
7
 
007
1
 
008
6
 
072
2
 
074
7
 
075
5
 
102
4
 
105
0
 
107
8
 
107
9
 
111
4
 
111
9
 
Pa
ra
met
e
Nu
mber
 
So
u
rce
 
Na
me
 
F
u
nct
io
n
al
 G
ro
u
pi
ng 
C
O
/B
O
: C
ontr
o
lw
ord
 2 
C
O
/B
O
: S
tatusw
ord 
1 f
o
r V
/F
 an
VC 
CO: A
ct. ma
x. 
cu
rr
en
CO: 
Max. ou
tp
ut v
o
lta
g
CO: A
ct. a
cti
ve
 c
urre
nt 
CO/B
O: B
inary
 in
put
 va
lu
es 
C
O
/B
O
S
tate of b
ina
ry ou
tp
uts 
CO: A
ct. A
DC ch
ar
ac
ter
ist
ic
 va
lu
[40 
CO: A
ct. f
ixe
fre
qu
en
cy 
CO:
 Ou
tp
u
t fr
eq
uen
cy
 of
 th
e
 MOP 
CO: 
Total fr
eq
ue
ncy se
tp
oint 
C
O
: S
e
lec
te
d
 fr
eq
uen
cy
 s
e
tp
oi
nt 
C
O
: F
req
uen
cy
 s
etpoi
nt 
af
ter
 D
IR
 
ctrl  CO: Freq
uen
cy
 s
etp. 
of 
th
e A
F
module 
0731 CIB  BI: Binary output 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0800 CIB  BI: Download parameter set 0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0801 CIB  BI: Download parameter set 1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0840 CIB  BI: CDS Bit 0 (local/remote) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0842 CIB BI: ON/OFF1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0844 CIB  BI: ON/OFF1 reverse 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0845 CIB  BI: 1. OFF2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0848 CIB  BI: 2. OFF2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0849 CIB  BI: 1. OFF3 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0852 CIB  BI: 2. OFF3 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1020 CIB BI: Pulse enable 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1021 CIB  BI: Fixed frequency selection bit 0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1022 CIB  BI: Fixed frequency selection bit 1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1032 CIB  BI: Fixed frequency selection bit 2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1035 CIB  BI: Enable MOP (UP-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1036 CIB  BI: Enable MOP (DOWN-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1055 CIB  BI: Enable JOG right 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1056 CIB  BI: Enable JOG left 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1074 CIB  BI: Disable additional setpoint 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1110 CIB  BI: Inhibit reverse direction 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1113 CIB BI: Reverse 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1124 CIB  BI: Enable JOG ramp times 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1140 CIB  BI: RFG enable 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1141 CIB  BI: RFG start 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1142 CIB  BI: RFG enable setpoint 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1230 CIB  BI: Enable DC braking 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2103 CIB  BI: 1. Faults acknowledgement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2104 CIB  BI: 2. Faults acknowledgement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2106 CIB  BI: External fault 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2220 CIB  BI: Fixed PID setpoint selection bit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2221 CIB  BI: Fixed PID setpoint selection bit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2222 CIB  BI: Fixed PID setpoint selection bit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2235 CIB  BI: Enable MOP (UP-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2236 CIB  BI: Enable MOP (DOWN-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0771 CIW CI: DAC 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1070 CID  CI: Main setpoint 
10
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1071 CIF  CI: Main setpoint scaling 
10
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1075 CID  CI: Additional setpoint 
10
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1076 CIF  CI: Additional setpoint scaling 
10
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2016 CIW  CI: PZD to BOP-Link (USS) 
20
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2019 CIW  CI: PZD to Comm-Link (USS) 
20
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2051 CIW  CI: PZD to CB 
20
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2200 CIB  BI: Enable PID controller 
22
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2253 CIF  CI: PID setpoint 
22
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2254 CIF  CI: PID trim source 
22
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2264 CIF  CI: PID feedback 
22