Fig. 5
1. Remove the bottom SUPPLY HOSE (1) from the 
SELECTRONIC ENCLOSURE (2). Fig. 3
2. Remove BOTTOM PLUG (3) from SELECTRONIC 
ENCLOSURE (2). Fig. 3 
3. Remove 4 screws from MIXER ENCLOSURE 
COVER (2) and pull off COVER (2). Fig. 3b
4. Remove MIXING VALVE (7) from ENCLOSURE (3). 
5. Install MIXER ENCLOSURE (4) under SELECTRONIC 
ENCLOSURE (2) as shown in Fig. (3a). Hold the MIXER 
ENCLOSURE (4) in that location and mark the four 
mounting hole locations as shown. Fig. (3a)
NOTE: MIXER ENCLOSURE SUPPLY HOSES are 
20" long. Distance between wall valves and MIXER 
ENCLOSURE (4) must be taken into consideration.
5. The ENCLOSURE (4) works best if secured to a wall 
stud or cross brace within the wall, using the SCREWS 
(5) supplied. If the MIXER ENCLOSURE (4) is to be 
installed on a tile or plaster wall the ANCHORS (6) and 
SCREWS (5) should be used.
6. For installations on drywall or tiled walls; use 
ANCHORS (6) and SCREWS (5) for securing MIXER 
ENCLOSURE (4) to finished wall. Drill four 1/4" dia. 
holes a minimum of 1-3/4" deep. Insert the four 
ANCHORS (6) flush with face of the finished wall.
Align the MIXER ENCLOSURE (4) and Install the 
MOUNTING SCREWS (5). Tighten to secure MIXER 
ENCLOSURE (4) to mounting surface.
1. Install MIXING VALVE (1) back into ENCLOSURE.
2. Install FIBER SEAL WASHER (4) on MIXING 
VALVE NIPPLE (3). Hold MIXING VALVE (1) in place 
with one hand and with your other hand thread 
SWIVEL NUT (2) onto MIXING VALVE NIPPLE (3). 
Fig. 4. Use an adjustable wrench to tighten SWIVEL 
NUT (2). Fig. 4a
3. Replace ENCLOSURE COVER and tighten securely.
1. Turn off hot and cold water supplies before 
beginning.
2. Connect FLEXIBLE SUPPLIES (1, 2) directly to wall 
supplies. Connection on MIXER supplies are 3/8" 
compression. Connect left supply to Hot and right 
supply to Cold wall supply. Use adjustable wrench to 
tighten connections. Do not over tighten. FIG. 5
3. Faucet supplies measure 20" from the bottom of the 
ENCLOSURE (3) base.
Note: If additional supply length is required, installer 
must purchase parts separately.
Important: If SUPPLY HOSES (1, 2) are too long, loop 
as to avoid kinking.
    MOUNT ENCLOSURE; Fig. 3
1
    CONNECT MIXING VALVE; Fig. 4
2
    CONNECT MIXING VALVE TO
WATER SUPPLIES; Fig. 5
3
2
Fig. 4
Fig. 4a
1
2
3
4
3
1
HOT
COLD
2
2
ADJUSTABLE 
WRENCH
WALL SUPPLIES
INSTALLATION
Fig. 3
Fig. 3a
Fig. 3b
4-1/4"
(108mm)
1-3/16"
(46mm)
4
2
MOUNTING HOLES
ILLUSTRATION SHOWN
LESS MIXING VALVE
1
3
SUPPLIES
WASTE
LAVATORY RIM OR
MOUNTING SURFACE
ENCLOSURE
MOUNTING
HOLES
2
6
4
5
7
Fig. 7d
Fig. 7a
Fig. 7e
In
s
t
a
ll
a
t
io
n
 I
n
s
t
r
u
c
t
io
n
s