Справочник Пользователя для Tally Genicom 6600

Скачать
Страница из 330
High Density Barcode
71
Example 1: Barcodes can be expanded by doubling the ratio of the light/dark 
bars. Code 39, which is normally 1:1:3:3 can be printed double 
wide by sending the Version 2 Graphics Pass, 
^M0505000^IBARC,C39,R2:2:6:6,E,12345^G^- prints:
Example 2: Barcodes can also be expanded by replacing the ratio numbers in 
Table 3, page 65, with other values that are not exact multiples. 
The Version 2 Graphics Pass, 
^M0505000^IBARC,UPCA,R2:3:4:6:6:8:8:9,E,1234567890^G^- 
prints:
High Density Barcode
Normally, barcodes print at 60 DPI horizontally. For improved readability, they 
may also print at 120 DPI. The 120 DPI, High Density Mode can be toggled 
ON and OFF by the command:
Command KF
Example:
The command sequence 
 
^M0505000^KF^IBARC,C39,B,MAU THE CAT^G^KF prints:
^KF first turns the High Density mode for barcodes ON, then the barcode is 
printed. The second ^KF turns High Density Mode OFF.
NOTE: Darkbar Control Panel settings overrides ^KF if Darkbar is ON.