 User’s Manual
 
 
 
4.1  Host Interface Signals 
ACT-IR100SD host interface consists of three output signals and five input signals. All these signals are 
low active. That is, they are at 0V when active and at VCC level when inactive. When an inverting RS232 
level converter is used, the corresponding RS232 level signals are high active. That is, they are at +12V 
nominal when active and at –12V nominal when inactive. 
 
4.  /TXD: serial data output. 
2. /RXD: serial data input.   
3. /RTS: output. When hardware flow control is enabled. Active /RTS means /RXD is ready to 
receive. Inactive /RTS means /RXD is not ready. 
4. /CTS: input. If hardware flow control is enabled, /CTS must be driven active to allow /TXD and 
inactive to forbid /TXD. If hardware flow control is disabled, /CTS is optional. 
5. /DSR: input. If connection control is enabled, /DSR must be driven active to allow IrDA connection 
and inactive to forbid a new connection or terminate an existing connection. If connection control 
is disabled, /DSR is optional. 
6. /DTR: output. If connection control is enabled, active /DTR means an IrDA connection is made. 
Inactive /DTR means there is no connection. 
7. /CD: input. Optional. 
8. /RI: input. Optional. 
 
4.2  RS-232C DTE DB-9P Connector 
 
Pin No. 
Name 
Descriptions 
I/O 
1 CD 
  Data Carrier Detect 
RXD  
Receiver 
Data 
3 TXD 
 
Transmitter 
Data 
4 DTR 
 
Data 
Terminal 
Ready O 
5 GND 
 
Signal 
Ground 
GND 
DSR 
  Data Set Ready 
RTS 
  Request to Send 
CTS 
  Clear to Send 
9 RI 
 
Ring 
Indicator 
 
 
 
 
 
 
 
 
 
 
 
 
Front View
 
 Copyright 2000-2006 ACTiSYS Corp. 
Page 9 of 17 
 
 