Справочник Пользователя для Alliance Laundry Systems F232182R1

Скачать
Страница из 34
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13
F232182
Programming
The V-computer board is inside the control module. 
Near the center of the board is a small toggle switch: 
this is the Run/Program Mode switch.
The Run/Program switch is normally in the down (Run 
Mode) position. To enter Program Mode, flip the 
switch to the up position. The display will now show 
the current temperature in the sump.
Figure 4 
Since the keypad operates in a slightly different 
fashion when in Program Mode, pay careful attention 
to the programming instructions provided in this 
manual.
Key Functions in Program Mode
Up – The Up key is used to increase cycle numbers 
(1 through 30) and other numerical values such as 
times or temperatures (when creating wash formulas).
Down – The Down key is used to decrease cycle 
numbers (1 through 30) and other numerical values 
such as times or temperatures (when creating wash 
formulas).
Start – The Start key acts as an enter key in Program 
Mode. Use this key to enter data and move to the next 
function in the cycle. 
Stop – The Stop key saves all data and terminates the 
programming procedure. If it is the first key pressed in 
Program Mode, the computer enters Setup Mode. The 
Stop key can be pressed again to exit Setup Mode and 
return to Program Mode.
Setup Mode
Setup options are programmable options that are in 
effect for all wash formulas. These options include:
Degrees displayed in Fahrenheit or Celsius
Auxiliary heat enabled or disabled
Supply 5 or Auxiliary fill
Temperature-controlled fill enabled or disabled
Automatic cool-down enabled or disabled
NOTE: These options can be read or changed only 
in Setup Mode.
To enter Setup Mode, press the Stop key while the 
display is showing the temperature in the sump. Once 
in Setup Mode, use the Up or Down key to change the 
selected option. Use the Start key to accept the 
selected option and move on to the next one. Press the 
Stop key to exit Setup Mode.
CHM474R
1
Run/Program Mode Switch
2
Temperature Calibration Screw
Dangerous voltages are present in the 
electrical control box(es) and at the motor 
terminals. Only qualified personnel 
familiar with electrical test procedures, 
test equipment, and safety precautions 
should attempt adjustments and 
troubleshooting. Disconnect power from 
the machine before removing the control 
box cover, and before attempting any 
service procedures.
SW005
WARNING
1
2