Справочник Пользователя для Alliance Laundry Systems F232182R1

Скачать
Страница из 34
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Safety
7
F232182
Water Damage. Do not spray the machine with 
water. Short circuiting and serious damage may 
result.
Machine Location
Foundation. The concrete floor must be of 
sufficient strength and thickness to handle the 
floor loads generated by the high extract speeds 
of the machine. 
Service/Maintenance Space. Provide sufficient 
space to allow comfortable performance of 
service procedures and routine preventive 
maintenance.
This is especially important in connection with 
machines equipped with an AC inverter drive. 
Consult installation instructions for specific details.
Input and Output Services
Water Pressure. Best performance will be 
realized if water is provided at a pressure of 
30 – 85 psi (2.0 – 5.7 bar). Although the machine 
will function properly at lower pressure, 
increased fill times will occur. Water pressure 
higher than 100 psi (6.7 bar) may result in 
damage to machine plumbing. Component 
failure(s) and personal injury could result.
Steam Heat (Optional) Pressure. Best 
performance will be realized if steam is provided 
at a pressure of 30 – 80 psi (2.0 – 5.4 bar). Steam 
pressure higher than 125 psi (8.5 bar) may result 
in damage to steam components and may cause 
personal injury.
For machines equipped with optional steam heat, 
install piping in accordance with approved 
commercial steam practices. Failure to install the 
supplied steam filter may void the warranty.
Compressed Air. For machines requiring 
compressed air service, best performance will 
be realized if air is provided at a pressure of 
80 – 100 psi (5.4 – 6.7 bar).
Drainage System. Provide drain lines or troughs 
large enough to accommodate the total number of 
gallons that could be dumped if all machines on 
the site drained at the same time from the highest 
attainable level. If troughs are used, they should 
be covered to support light foot traffic.
Power. For personal safety and for proper 
operation, the machine must be grounded in 
accordance with state and local codes. The 
ground connection must be to a proven earth 
ground, not to conduit or water pipes. Do not use 
fuses in place of the circuit breaker. An easy-
access cutoff switch should also be provided.
Always disconnect power and water supplies before a 
service technician performs any service procedure. 
Where applicable, steam and/or compressed air supplies 
should also be disconnected before service is performed.
Do not place volatile or flammable fluids 
in any machine. Do not clean the machine 
with volatile or flammable fluids such as 
acetone, lacquer thinners, enamel 
reducers, carbon tetrachloride, gasoline, 
benzene, naptha, etc. Doing so could 
result in serious personal injury and/or 
damage to the machine.
SW002
DANGER
Replace all panels that are removed to 
perform service and maintenance 
procedures. Do not operate the machine 
with missing guards or with broken or 
missing parts. Do not bypass any safety 
devices.
SW019
CAUTION
Ensure that a ground wire from a proven 
earth ground is connected to the ground 
lug near the input power block on this 
machine. Without proper grounding, 
personal injury from electric shock could 
occur and machine malfunctions may be 
evident. 
SW008
WARNING