Справочник Пользователя для TEAC CD-RW901

Скачать
Страница из 40
 
TASCAM  CD-RW901
When audio signal is not detected for more than five 
seconds, the CD-RW901 automatically will stop record-
ing and enter record standby mode.
S_LVL
REC ready
level
time
Five seconds
NOTE
When the input level drops below the adjusted 
threshold level for more than five seconds, record-
ing stops automatically and enters in recording 
ready mode.
3.  To cancel the Sync recording mode, press the
SYNC REC
key. Recording returns to normal
and continues till you press the
STOP
key or the
source signal stops.
Pressing the
STOP
key stops recording.
The setting remains when the function is set on
again.
NOTE
If you set the value so that only high-level signals 
trigger recording, remember that the start of a 
piece  may not be record as in the diagram.
Recordsing starts
level
time
This  part  of  the
track may not be
recorded
S_LVL
Also remember that when recording from an ana-
log source, the threshold should be set so that it is 
higher than the “noise floor”. If the “noise floor” is 
higher than the threshold, a false start will occur: 
S_LVL
level
time
Noise  is  higher
than threshold
Start of track is not registered
Sync recording with trim function
This Sync trim function allows you to override the auto-
matic sync recording where necessary, to chang the start
time of the track forwards or backwards.
Use the SYNC TRIM option in the REC sub-menu to 
turn the function on (see “Operation basics” on page 
16).
The available trim range is from -125 through +125 
frames.
Turn the
MULTI JOG
 dial to adjust the trim value.
Automatic track division
The trigger level can also be used to divide tracks if the 
A_TRACK (auto track) function is enabled.
When this function is enabled, the unit automatically 
inserts a track division in the recorded material.
To enable or disable automatic track division:
1.  Use A_TRK option in the REC sub-menu to set
the mode on. The
A.TRACK
indicator at the top right
of the display lights.
2.  Rotate and push the
MULTI JOG
dial to select
and enter the modes following:
DD (digital direct)
  When recording digitally from MD, CD or DAT, this 
mode detects a track boundary and divides the track. 
However, when the DD mode is on, and if the analog 
source or non-DAT/CD/MD digital connections are 
detected, the track number will be incremented using 
level detection, as set with the A_TRK LEVEL set-
ting as described here.
  When AES/EBU is selected, this mode cannot be 
used.
Level
  When the sound level has dropped below the thresh-
old for more than two seconds, and sound has 
re-started, the track will be divided. 
  Use A_TRK LEVEL option in the REC sub-menu. 
The trigger level is set to -24dB to -72 dB.
A_LVL
At least
2 seconds
level
time
Track increment
5 − Recording