electrical Tasks Before Spa delivery
if installing a spa that is …
Then it must be …
240V (North America)
Hard wired to the power supply.
120V (USA only)
Plugged into a dedicated grounded outlet using the 
GFCI cord supplied with the spa.
120V (Canada)
Hard wired to the power supply per CSA standards.
Continued on next page
General Electrical System Considerations
+
Before the installation of your spa begins, check with the local building 
department to ensure this installation conforms to local building codes.
important 
When installed in the United States, the electrical wiring of this spa 
must meet the requirements of the National Electric Code (NEC) 
and any applicable state or local codes. The electrical circuit must 
be installed by an electrical contractor AND approved by a local 
building/electrical inspector.
N
 
ever use an extension cord of any kind. Using an extension cord can 
damage the spa equipment and void your warranty. 
The Sundance Denali, Dover, and Tacoma North American models include 
a 10 foot GFCI cord for plug-in 120V operation. Connect this cord directly 
to a dedicated/grounded wall outlet. When a power cord over 10 ft. is 
required, the spas must be hard wired in accordance with state and local 
codes.
Before the scheduled arrival of your spa, it is necessary to set up the electrical 
components. Use the checklist below to prepare for the spa’s installation.
Prepare the electrical connection for your spa based on one of the configurations listed 
below. If necessary, refer to the Power Configuration tables for additional information by 
model.