Справочник Пользователя для Sundance Spas spas 880 series

Скачать
Страница из 32
20
Installing a 3-Wire 240 VAC Connection for 880 Altamar, Cameo, Capri, 
Majesta, Marin, Maxxus, Optima Models, 780 Camden, Certa, Chelsee, 
Hamilton Models, and 680 Burlington, Hartford and Hawthorne Models 
electrical Tasks After Spa delivery, 
Continued
Continued on next page
Figure 3: Spa equipment compartment
Power Supply Inlets
Attach to a 
Sundance 
Ozone Unit 
(Aftermarket 
purchase)
Control Box
Hot T
ub
Control Box
TB1
Terminal
Ground/
Bonding Lug
Note: TB1 terminal location will vary between 
models; 3-wire/240 VAC connection illustrated
Figure 4:
Control Box
The Control Box for 3-wire, 240 VAC 
connection
The location of the TB1 terminal may vary 
between models.
TB1
Red (L2)
Red
Green
Black (L1)
Black
Figure 5A:
3-Wire/240 VAC Connection
for 880 Altamar, Cameo, Capri, 
Majesta, Marin, Maxxus, Optima, 
Models.
Hard Wired Connections Only.
External
Power
To spa circuit
TB1
Figure 5B:
3-Wire/240 VAC Connection
for 780 Camden, Certa, 
Chelsee, Hamilton, and 
680 Burlington, Hartford, 
Hawthorne Models.
Hard Wired Connections Only.
Black
 (L2)
Black
Red
 (L1)
Red
Green
To spa
circuit
External Power