A pressure sensitive 
terminal block (bonding 
lug) is attached to the 
outside surface of the 
load box. This permits the 
connection of a bonding 
wire between this point 
and any metal equipment 
chassis, metal water pipe, 
or metal conduit within 5 
ft (1.5m) of the spa. The 
bonding wire must be at 
least #8 AWG (8.4 mm
²
solid copper wire. 
Red (L2)
Red (L2)
Pigtail
Neutral Bus
Ground
TB2
Black (L1)
Black (L1)
Green
GFCI Sub Panel*
Main Panel*
2-Pole 
GFCI
Breaker
Ground/Bonding Lug**
No Load Neutral Wire
Main Panel with Secondary GFCI Shut-Off Box Using a
2-Pole GFCI Breaker with 2-Wire Grounded Connection
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
TB1
White (N)
Green (Ground)
*GFCI Sub Panel commonly 
used when recommended GFCI 
does not install in Main Panel.
Note: service disconnect not 
shown in this diagram.  
The control box TB1 terminal 
position varies between models.
B
R
Hot Tub
Contr
ol Box
Red (L2)
Pigtail
Neutral Bus
Ground
TB2
TB1
Black (L1)
Green
Main
Service
Panel
with
GFCI
2-Pole 
GFCI
Breaker
Ground/Bonding Lug**
2-Pole Circuit Breaker with 2-Wire Grounded Load Connection
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
White (N)
Black (L1)
Red (L2)
240 VAC
No Load Neutral Wire
Note: service disconnect not 
shown in this diagram.  
The control box TB1 terminal 
position varies between models.
B
R
Hot Tub
Contr
ol Box
Connection Configuration #1 
240 vAC Connections for 880 Altamar, Cameo, Capri, Majesta, Marin, 
Optima, Maxxus, 780 Camden, Certa, Chelsee, Hamilton Models, 680 
Burlington, Hartford, Hawthorne Models (North America 60 Hz)