Section 7.2 - Unit-related functions  
7-6 
7.2.12 Confidence mode
 The DA-98 allows off-tape monitoring while 
recording (confidence mode). This can be 
switched on or off on a per-machie basis.
However, since there is a slight delay between the 
input signal and its replay in confidence mode, 
you should not use confidence mode in the follow-
ing circumstances:
When making punch recordings, as you will 
not be able to hear the exact timings for punch 
operations.
When operating a mixed chain of DA-98s and 
other units. The delay introduced by confi-
dence mode on the DA-98 will make these 
tracks appear to be out of time with the other 
tracks.
However, confidence mode can be very useful 
when making test recordings so that you can 
instantly hear the effects of different dither set-
tings (see 7.2.11, “Dither”), or to monitor possible 
clipping at high recording levels on a test take, 
allowing you to “back off” the level a little before 
making a final recording.
1) From menu group 9, move the cursor to 
ConfdMod
 and press 
SELECT
:
2) Use the 
UP
 and 
DOWN
 keys to select between 
the three states: 
off
ready
 and 
on
.
Confidence mode is selected using this three-state 
switch to prevent accidental switching of the unit 
into confidence mode, which might otherwise 
cause confusion when performing monitoring 
operations.
7.2.13 Reference levels
The reference level for analog I/O on the DA-
98 can be set to one of three standard values: 
European, TASCAM and SMPTE. These levels 
correspond to:
1) From menu group 2, move the cursor to 
Ref 
Level
 and press 
SELECT
:
2) Use the UP and DOWN keys to select between 
-16
-18
 and 
-20
 dB.
The appropriate reference level indicator(s) next to 
the meters on the DA-98 unit will light. See sec-
tion 8-7 of the DA-98 manual for further details of 
reference levels.
7.2.14 Meter modes
On the DA-98, the peak hold time and the 
decay ballistics of the meters can be changed.
1) From menu group 2, move the cursor to 
MeterMode
 and press 
SELECT
:
2) Move the cursor to the 
Peak Hold
 setting, 
and choose between the following values: 
0
 
through 
9
 seconds (in 1-second increments) 
and 
continue
.
The 
continue
 setting sets an infinite peak 
hold time. The peak levels can be reset by setting 
the time to 
0
 seconds.
3) Move the cursor to the 
Release
 setting, and 
choose between the following release times: 
Fast
Medium
 and 
Slow
.
The meter functions are described in section 8.8 of 
the DA-98 manual.
7.2.15 Sine oscillator
The DA-98 incorporates a sine oscillator for 
line-up purposes at either 440Hz or 1kHz. The 
level of the oscillator is a full bit +16dBu (but can-
not be compared to transient signals, on account 
of the constant nature of a sine-wave oscillator).
C o n f i d e n c e
M o d e
M a c h i n e
1
o f f
Standard
Reference 
level
Nominal 
level
Maximu
m level
TASCAM
–16dBFS
+4dBu
+20dBu
European
–18dBFS
+4dBu
+22dBu
SMPTE
–20dBFS
+4dBu
+24dBu