Справочник Пользователя для Alliance Laundry Systems sc50

Скачать
Страница из 150
Maintenance
64
F232062
Monthly
 (Continued)
5. Clean inlet hose filter screens: 
a. Turn water off and allow valve to cool, 
if necessary. 
b. Unscrew inlet hose and remove 
filter screen. 
c. Clean with soapy water and reinstall. 
Replace if worn or damaged.
6. Tighten motor mounting bolt locknuts and 
bearing bolt locknuts, if necessary.
7. Use compressed air to clean lint
from motor.
8. Clean interior of machine, both basket and 
shell, by wiping with a water-soaked 
sponge or cloth.
9. Use compressed air to ensure that all 
electrical components are free of moisture 
and dust.
10. For variable-speed models only, clean 
AC drive cooling fan blades monthly 
(more often if required by the condition of 
the air).
a. Open the top cover and remove the 
control module cover.
b. Gently wipe the fan blades clean with a 
dry cloth.
Quarterly
Note: Disconnect power to the machine 
before performing the quarterly maintenance 
procedures.
1. Tighten door hinges and fasteners, 
if necessary.
2. Tighten anchor bolts, if necessary.
3. Verify that the drain motor shield is in 
place and secure.
4. Check all painted surfaces for bare metal. 
(Matching gray paint is available from the 
manufacturer.)
• If bare metal is showing, paint with 
primer or solvent-based paint. 
• If rust appears, remove it with 
sandpaper or by chemical means. 
Then paint with primer or solvent-
based paint. 
5. Clean steam filter, where applicable. See 
Figure 52.
a. Turn off steam supply and allow time 
for the valve to cool.
b. Unscrew cap. 
c. Remove element and clean. 
d. Replace element and cap.
Figure 52
H042IE1A
Cap
Filter
Element