Справочник Пользователя для alpha-industries mtk005

Скачать
Страница из 12
3
INTroduCTIoN
Thank you for purchasing the alpha
®
 Moisture Test Kit, a calcium chloride test for 
determining if the concrete slab is suitable for floor covering or polymer coating 
installations.
The test works by absorbing moisture in a vapor form that is exiting the slab’s 
surface due to natural environmental factors over a period of time. 
The test measures an approximate 70 square inches area of concrete surface for 
60 to 72 hours, then a simple calculation is followed that determines the volume 
of the vapor emission. 
The Moisture Vapor Emission Rate (MVER) is the equivalent weight of water (if 
the gas turned into liquid) that emits from 1,000 square feet of concrete surface 
area in 24 hours time.
 
  CauTIoN!
To ensure correct use, read this Instruction Manual and the product’s Limited 
Warranty and Terms of sales prior to use of this product. The use of the product 
implies that the Buyer and User agrees to Manufacturer’s Limited Warranty and 
Terms of sale.  Keep this manual in a place where operators can access it easily 
whenever necessary!
asTM f 1869 ProToCol CHeCKlIsT for CoNduCTING 
THe CalCIuM CHlorIde TesT
before starting the test, make sure the following conditions are met: 
1.  Provide the number of test kits required.
Install 3 test kits for areas up to 1,000 sq. ft or smaller, add 1 test kit for each 
additional 1,000 sq. ft. area thereafter. 
2.  Ensure interior environment is conditioned correctly before performing 
tests. 
a properly conditioned building interior has a temperature between 65 to 85 
degrees F. with a relative humidity of 40 to 60 % for at least 48 hours before 
the test begins and remains consistent throughout the testing period of 60 to 
72 hours. Record values on log sheet.