Справочник Пользователя для Sundance Spas 680

Скачать
Страница из 44
Page 7
this point and any ground metal equipment, metal water pipe or conduit 
within 5 feet (.5m) of the spa, or copper clad grounding rod buried 
within 5 feet (.5m) of the spa. Bonding wire must be at least No. 8 
AWG (8.4mm
2
) solid copper wire. This is a most important safety assur-
ance feature.  
Before installing your spa, check with your local building department to 
insure installation conforms to local building codes.
120/240 Volt Denali And Tacoma Convertible models
A spa connected to a 20 VAC electrical service must be located 
close enough to a grounded, grounding-type electrical outlet so that 
the included power cord can be plugged directly into it. DO NOT USE 
AN EXTENSION CORD
 as this could cause damage to the spa’s 
equipment due to insufficient voltage. The power supplied to this spa 
must be a dedicated circuit with no other appliances or lights sharing 
the power provided by the circuit. 
4.0 Choosing A Location
ImpORTANT: Because of the combined weight of the spa, water and 
users, it is extremely important that the base upon which the spa rests 
be smooth, flat, level and capable of uniformly supporting this weight, 
without shifting or settling, for the entire time the spa is in place. If the 
spa is placed on a surface which does not meet these requirements, 
damage to the skirt and/or the spa shell may result. Damage caused by 
improper support is not covered under warranty. It is the responsibility of 
the spa owner to assure the integrity of the support over time.
We recommend a poured, reinforced concrete slab with a minimum 
thickness of 4 inches (0cm). Wood decking is also acceptable provided 
it is constructed so that it meets the requirements outlined above.  The 
spa must be installed in such a manner as to provide drainage away 
from the spa. Placing the spa in a depression without provisions for 
proper drainage could allow rain, overflow and other casual water 
to flood the equipment and create a wet condition in which it would 
sit.  For spas which will be recessed into a floor or deck, install so as 
to permit access to the equipment, either from above or below, for 
servicing. Make certain that there are no obstructions which would 
prevent removal of the cabinet side panels and access to the jets 
components, especially on the side with the equipment bay doors.