Справочник Пользователя для RAD Data comm ASM-60

Скачать
Страница из 90
 
Preparing for the Control Session 
4-1 
Chapter 4 
Management from a 
Terminal 
The configuration of ASM-60 is performed via menu-driven embedded software 
using a standard ASCII terminal or a PC running a terminal emulation application 
connected to the front panel CONTROL DCE port. This terminal can be used for 
performing the following management activities supported by ASM-60: 
•  Modifying setup configuration 
•  Monitoring of device status and settings 
•  Collect performance statistics 
•  Restarting ASM-60. 
4.1  Preparing for the Control Session 
This section describes how to prepare ASM-60 and supervisory terminal for the 
control session. 
Control Port Interface Characteristics 
ASM-60 includes a V.24/RS-232 asynchronous DCE port, designated CONTROL 
DCE and terminated in a 9-pin D-type female connector. The control port 
continuously monitors the incoming data stream and will immediately respond to 
any input string received through this port. 
The terminal can be connected either directly to the ASM-60 control port, or 
through a modem or any other type of full-duplex data link. The ASM-60 control 
port interface type must be set in accordance with the connection method, as 
follows: 
Preparing Terminal  
Any standard ASCII terminal (a “dumb” terminal or a personal computer running 
terminal emulation application) equipped with a V.24/RS-232 communication 
interface can be used to configure ASM-60. 
Control Port Handshaking Protocol 
The control lines used in each DCE and DTE mode and the direction of the control 
signals are detailed in the following table.