Installation
This Owner’s Guide provides visual assembly reference only. Since specialized skills are
required in the assembly of  the drinking water system, we recommend that you contact
your local independently operated Culligan dealer to complete this installation.
APPLICATION GUIDELINES
The Aqua-Cleer
®
 Good Water Machine
 is designed for use on potable water supplies
meeting the guidelines outlined in Table 1.  The system should be installed on your
home’s cold water line.  The flushing stream should discharge through an approved
siphon break as illustrated in Figure 1.  Installation of this system must comply with
state and local laws and regulations.
TABLE 1
Influent Water Characteristic
Pressure
40 - 120 psi (280 - 827 kPa)
Temperature
33 - 100°F (1 - 38°C)
Total Dissolved Solids (TDS)
1
0 - 2500 ppm ( 0 - 2500 mg/L)
pH
5 - 10
Chlorine
2
0 - 3 ppm ( 0 - 3 mg/L)
Chloramine
0 - 3 ppm ( 0 - 3 mg/L)
Turbidity
0 - 10 NTU
Hardness
0 - 20 gpg
Iron
0 - 1 ppm (0 - 1 mg/L)
Bacterial Quality
Potable
1 See the Technical Manual for all applications where TDS exceeds 1000 ppm (1000 mg/L). A booster pump is
strongly recommended.
2 The reverse osmosis membrane filter used in this system may be damaged by chlorine. This system includes
activated carbon which protects this element by reducing chlorine. Influent chlorine should not exceed 3 mg/L.
3 A softener is strongly recommended for water over 10 gpg.