Справочник Пользователя для Pelco CCC1390H-6K

Скачать
Страница из 2
 
C2924M-QS (4/05)
 
LENS
 
The CCC1390H Series camera supports both manual and DC-drive auto iris lenses, either fixed focal 
length or varifocal. It automatically senses an auto iris lens as soon as you plug in the connector. 
The camera has a standard CS-mount that can accept a C-mount lens with a PCMA40 lens adapter.
To mount the lens onto the camera:
1. Use clean, compressed air or a clean, dry lens cloth to make sure there is no dust or other foreign 
matter between the lens and the camera imager.
2.
 
C-mount lens:
 
 Screw the adapter onto the lens.
3. Screw the lens onto the lens mount.
4.
 
DC-drive auto iris lens:
 
 Connect the four-pin connector from the lens to the connector on the 
back of the camera.
 
MOUNT
 
The CCC1390H Series camera can be mounted from either the top or bottom, depending on the type of 
camera mount used in your installation. Use a standard 1/4-20 screw. The maximum thread depth (top) 
is 0.188 inches (4.7 mm). To extend the thread depth (top) to 0.25 inches (6.4 mm), use the camera mount 
spacer (supplied). The maximum thread depth (bottom) is 0.25 inches (6.4 mm).
 
ELECTRICAL 
 
Power
 
Connect 12 VDC or 24 VAC power to the three-pin terminal strip on the back of the camera. Use a Class 2 
isolated power source for the CCC1390H camera that can supply 12 VDC ±15% or 24 VAC ±15%, 
50/60 Hz. Maximum power consumption is about 3.5 watts.
 
Video
 
Connect a coaxial video cable to the BNC connector on the back of the camera.
 
External Control
 
For serial control, install the control connector (refer to 
 
Connecting External Control
 
 in the Installation/
Operation manual for more information).
 
ACCESSING THE SETUP MENUS
 
Use the five-position button on the rear panel to access and navigate the setup menus. The following 
table lists the button presses for each menu action.
 
MENU ACTION
BUTTON ACTION
 
Enter setup menus.
Long center press
Move up or down in menu or item options.
Up or down press
Move right or left in menu.
Right or left press
Select menu or item.
Short center press
Save setting and exit to menu.
Short center press
 
NOTE:
 
  After you customize any aspect of the CCC1390H Series camera, be sure to save your custom 
settings. (Refer to 
 
Profiles
 
 in the Installation/Operation manual for information about saving custom 
settings.)
 
LENS FOCUS
 
After mounting the lens, you must focus your CCC1390H Series camera. You will adjust both the back 
focus (on the camera) and the fine focus (on the lens).
 
NOTE: 
 
 The back focus has already been adjusted using a standard CS-mount lens. However, you might 
need to adjust it again to match the mounted lens.
1.
 
Auto iris only:
 
 Cover the auto iris lens 
with a suitable neutral density (ND) filter. 
This opens the iris fully. For best results, 
use an ND3 filter.
2.
 
Manual iris only:
 
 Open the iris 
completely. The figure shows the manual 
iris, varifocal, and lens focus locking 
screws for a sample lens. Refer to your 
lens documentation for more 
information.
3. If necessary, enable Automatic Gain 
Control (AGC) on the EXPOSURE 
SETTINGS menu. AGC is enabled by 
default.
a.
Display the EXPOSURE 
SETTINGS menu.
b.
Change AGC to ON.
c.
Select EXIT to save the AGC 
setting.
4. Aim the camera at the farthest object in the field of view. Make sure it is at least 6.5 ft (2 m) away.
5.
 
Fixed focal length lens only:
 
 
a.
Set the lens focal length to far (
 
 
).
b.
Adjust the back focus:
 
(1)
Use a 1.5-mm Allen wrench to loosen the back focus locking screw.
(2)
Turn the lens until the image is focused. 
(3)
Tighten the back focus locking screw clockwise.
 
Back focus is a coarse adjustment. You will make the fine focus adjustment in the next step.
c.
Adjust the lens focus to achieve the best fine focus.
 
WARNING:
 
  Do not over-tighten the back focus locking screw because you may damage the 
camera.
1.5 MM
ALLEN
WRENCH
VARIFOCAL
LOCKING
SCREW
LENS FOCUS
LOCKING SCREW
MANUAL IRIS
LOCKING SCREW
 
6.
 
Varifocal lens only:
 
 
a.
Set the varifocal to wide (W) and the lens focal length to far (
 
 
).
b.
Adjust the back focus:
 
(1)
Use a 1.5-mm Allen wrench to loosen the back focus locking screw.
(2)
Turn the lens until the image is focused.
(3)
Tighten the back focus locking screw clockwise.
 
Back focus is a coarse adjustment. You will make the fine focus adjustment in steps c and d.
c.
Move the varifocal locking screw up or down to set the field of view.
d.
Adjust the lens focus to achieve the best fine focus.
e.
Repeat steps c and d until the focus is correct.
7.
 
Manual iris only:
 
 Adjust the iris for the best picture quality. The largest aperture gives the best 
light sensitivity; the smallest aperture gives the greatest depth of field.
8. Tighten all lens locking screws.
 
NOTE:
 
  When tightening the lens locking screws, do not over-turn or force any screw.
9.
 
Auto iris only:
 
 Remove the ND filter.
10. If necessary, disable AGC:
a.
Display the EXPOSURE SETTINGS menu.
b.
Change AGC to OFF.
c.
Select EXIT to save the AGC setting.
11.
 
Auto iris only:
 
 Perform the auto iris lens adjustment procedure (refer to 
 
Auto Iris Lens 
Adjustment
 
 in the Installation/Operation manual for more information).
12. As soon as you finish customizing this and all other camera settings, save your custom settings 
into the CUSTOM profile. This protects them in case the camera loses power or must be restarted 
(refer to 
 
Profiles 
 
in the Installation/Operation manual for more information).
 
WARNING:
 
  Do not over-tighten the back focus locking screw because you may damage the 
camera.
REVISION HISTORY
Manual # 
Date 
Comments
C2924M-QS 4/05 Original 
version.
Pelco and the Pelco logo are registered trademarks of Pelco. 
©Copyright 2005, Pelco. All rights reserved.
Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA •  www.pelco.com
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120
 
C2924M-QS.fm  Page 2  Wednesday, April 27, 2005  3:26 PM