Справочник Пользователя для Pelco MPT9500TD

Скачать
Страница из 20
Pelco Manual C535M-B (8/98)
19
5.0  SPECIFICATIONS
ELECTRICAL
Input Voltage:
(50/60 Hz) 120, 230 VAC
Power
Consumption:
12 watts
Control Method:
Coaxitron
®
 VIS
4-wire RS-485
Standard
Baud Rates:
VIS 1 MHz
RS-485 2400 baud
Command
Error Rates:
DUPLEX 0%
SIMPLEX 2%
Input Video Level:
0.5 to 1.5 Vp-p
Operating
Distances:
VIS - 2000 ft (609m) on RG-11
RS-485 - 4000 ft (1,219m)
24 AWG-TP
MECHANICAL
Connectors:
Video
3 BNCs
Power
3-wire #18 AWG molded
Fuse
1/4 ASB @ 120 VAC
1/8 ASB @ 230 VAC
RS-485
RJ-45 6-pin modular
GENERAL
Operating
Temperature:
0 to 120° F (-18 to 49° C)
Dimensions:
See Figure 8
Rating:
NEMA 1
(Design and product specifications subject to change without notice.)
NOTE:
  Operating distances are
calculated and based on typical
performance. The actual calcula-
tions are explained in the installa-
tion section of this manual and
should be done for each applica-
tion prior to installation.
Figure 8.  MPT9500 and MPT9500TD Dimension Drawing