Справочник Пользователя для Chamberlain security hd200dm

Скачать
Страница из 40
4
Safety Reversing Sensor
Horizontal and vertical reinforcement
is needed for lightweight garage doors
(fiberglass, steel, aluminum,
door with glass panels, etc.).
See page 23 for details.
 — — —        — — —        — —
Header Wall
Safety
Reversing
Sensor
Gap between floor and bottom of door
must not exceed 1/4" (6 mm).
Extension Spring
Torsion Spring
Access 
Door
OR
Slack in chain tension
is normal when
garage door is closed.
Wall-mounted
Door 
Control
Motor Unit
FINISHED CEILING
Support bracket & 
fastening hardware
is required.
See page 16.
Vertical 
Centerline
of Garage Door
SECTIONAL DOOR INSTALLATION
Planning
Identify the type and height of your garage door. Survey 
your garage area to see if any of the conditions below 
apply to your installation. Additional materials may be 
required. You may find it helpful to refer back to this page 
and the accompanying illustrations as you proceed with 
the installation of your opener.
Depending on your requirements, there are several 
installation steps which may call for materials or hardware 
not included in the carton.
•  
Installation Step 1 – Look at the wall or ceiling above 
the garage door. The header bracket must be securely 
fastened to structural supports.
•  
 Installation Step 5 – Do you have a finished ceiling in 
your garage? If so, a support bracket and additional 
fastening hardware may be required.
•  
Installation Step 10 – Depending upon garage 
construction, extension brackets or wood blocks may be 
needed to install sensors.
•  
Installation Step 10 – Alternate floor mounting of the 
safety reversing sensor will require hardware not 
provided.
Trolley
stop bolt
Header
Bracket
Trolley
Straight
Door
Arm
Emergency
Release
Rope & Handle
Door Bracket
 
Garage
Door
Curved
Door
Arm
Garage
Door
Spring
Header
Wall
Chain
CLOSED POSITION
•  
Do you have an access door in addition to the garage 
door? If not, Model 7702CB Emergency Key Release is 
required. See Accessories page.
•  
Look at the garage door where it meets the floor. Any 
gap between the floor and the bottom of the door must 
not exceed 1/4" (6 mm). Otherwise, the safety reversal 
system may not work properly. See Adjustment Step 3. 
Floor or door should be repaired.
SECTIONAL DOOR INSTALLATIONS
•  
Do you have a steel, aluminum, fiberglass or glass 
panel door? If so, horizontal and vertical 
reinforce ment is required (Installation Step 11). 
•  
The opener should be installed above the center of the 
door. If there is a torsion spring or center bearing plate 
in the way of the header bracket, it may be installed 
within 4 feet (1.22 m) to the left or right of the door 
center. See Installation Steps 1 and 11.
•  
If your door is more than 7 feet (2.13 m) high, see rail 
extension kits listed on Accessories page.