                                                                 Page 10 of 15                                         Rev: 1/21/2014 7:29 AM 
4)  When long beep stops, release Set button
 
A few seconds will pass 
SwitchLinc will double-beep 
The connected load will turn on 
 
X10 Setup 
SwitchLinc ships with no X10 address assigned.  
Add X10 Address 
1)  Turn SwitchLinc on. 
2)  Press and hold Set button until it beeps. 
LED will start blinking green
 
3)  Send the X10 address 3 times (with or without commands) 
SwitchLinc will double-beep and LED will stop blinking 
4)  Test by sending X10 on and off commands 
SwitchLinc will turn on and off 
Remove X10 Address 
1)  Press and hold Set button until it beeps 
LED will start blinking green
 
2)  Press and hold Set button until it beeps 
LED will start blinking red
 
3)  Send the X10 address 3 times (with or without commands) 
SwitchLinc will double-beep and LED will stop blinking 
5)  Test by sending X10 on and off commands 
SwitchLinc will no longer respond 
Other X10 Setup 
For other X10 setup instructions visit 
 
Local Settings 
Local On-Level 
Default = 100% (fixed brightness) The local on-level is the brightness that SwitchLinc’s connected load 
will come on when turned on at SwitchLinc paddle. Local on-level can be set to any one of 32 fixed 
brightness levels (3% to 100%) or “resume bright” (brightness prior to last being turned off). 
To set local on-level to a fixed brightness level 
1)  Adjust SwitchLinc to desired brightness when controlled locally 
2)  Tap Set button 
 
 
SwitchLinc will beep
 
3)  Test by turning SwitchLinc off and then back on (via the paddle) 
SwitchLinc will turn on to new local on-level
 
 
To set local on-level to the brightness level prior to being turned off 
1)  Turn SwitchLinc off