Справочник Пользователя для INSTEON 2477dhxxx

Скачать
Страница из 15
                                                                 Page 13 of 15                                         Rev: 1/21/2014 7:29 AM 
X10 status response 
Supported 
X10 resume dim 
Supported (by setting local on-level to zero) 
X10 minimum transmit level 
3.2 Vpp into 5 Ohms 
X10 minimum receive level 
20mV into 5 Ohms 
Mechanical 
Mounting 
Mounts in single or multiple-ganged junction box. Control 200W less load for 
each immediately adjacent SwitchLinc Dimmer installed. For example, 600 W 
load control becomes 400 W with another dimmer to the immediate right or left. 
Use a triple-gang box with a mechanical switch in the center to avoid de-rating. 
Wires 
Line (black) 
Load (red) 
Neutral (white) 
Ground (bare copper) 
Case color 
White 
Switch paddle and frame color 
White 
Set button 
Yes 
Plastic 
UV stabilized polycarbonate 
Beeper 
Yes 
Beep on button press 
Optional (off by default) 
Status LEDs 
1 dual-color red/green and 9 white 
Dimensions 
4.1” H x 1.8” W x 1.2” D 
Weight 
3.6 oz. (102 grams) 
Operating environment 
Indoors 
Operating temperature range 
32
°
 to 104
°
 F (0
°
 to 40
°
 C) 
Operating humidity range 
0-85% relative humidity 
Storage temperature range 
-4
°
 to 158
°
 F (-20
°
 to 70
°
 C) 
Electrical 
Voltage 
120VAC (+/- 10%), 60 Hz, single phase 
Neutral connection required 
Yes 
Frequency 
915 MHz 
Load type(s) 
Wired-in incandescent lighting fixtures 
Maximum load 
1000 watts (uses 12 Amp triac dimmer) 
User replaceable fuse 
No 
Hardwired remote control 
No 
Retains all settings without power 
Yes, saved in non-volatile EEPROM 
Standby power consumption 
0.59 watts 
Certifications 
FCC, IC Canada 
Safety approval(s) 
ETL (Intertek Testing Services) to UL/ANSI standard 
 
Troubleshooting 
Problem 
Possible Cause 
Solution 
SwitchLinc’s LEDs and connected load 
will not turn on 
SwitchLinc is not getting power 
Make sure the circuit breaker is turned 
on 
Check the light fixture to ensure all 
connections are tight and no bare wires 
are exposed