Connecting Stacked Switches
Note:  The two ends of the Octaplane cable terminate with different connectors. 
Each connector can only be connected to its matching port.
The following cables are used to connect stacked switches:
Short Octaplane cable (X330SC) – ivory-colored, used to connect adjacent 
switches (Catalog No. CB0223) or switches separated by a BUPS unit.
Long Octaplane cable (X330LC) – ivory-colored, used to connect switches from 
two different physical stacks, or switches separated by a BUPS unit (Catalog No. 
CB0225).
Redundant cable (X330RC) – black, used to connect the top and bottom 
switches of a stack (Catalog No. CB0222).
To connect stacked switches:
1
Plug the light grey connector of the Short Octaplane cable into the port marked 
“to upper unit” of the bottom Cajun P330 switch.
2
Plug dark grey connector of same Short Octaplane cable to the port marked “to 
lower unit” in the unit above. The connections are illustrated in Figure 4.3.
3
Repeat Steps 1 and 2 until you reach the top switch in the stack.
Note:  If you have split the stack, use the Long Cable instead of the Short Cable 
where required.
4
If you wish to implement stack redundancy, use the Redundant Cable to 
connect the the port marked “ to lower unit” on the bottom switch to the port 
marked “to upper unit” on top switch of the stack.
Caution:  Do not cross connect two Cajun P333T switches with two Octaplane 
(light-colored) cables. If you wish to cross-connect for redundancy, use one light-
colored Octaplane cable and one black redundancy cable. Figure 4.2 shows an 
incorrect connection.
Note:  You can build a stack of up to 10 Cajun P330 switches. If you do not wish to 
stack all the switches in a single rack, use long Octaplane cables to connect two 
physical stacks as shown in Figure 4.3.