Table 6 - II
  Error Messages, Pneumatic-related
iQ
 Pneumatic Press Error Messages
Error Message
Description
Cause(s)
Possible Solution(s)
Overload (average) at  xxx msecs. Power above  generator rating.
Power from ultrasonic stack sent to the  part exceeds power rating of generator
.
1. Excessive pressure applied to the part. 2. Booster size is too large.
1. Decrease pressure applied to part. 2. Reduce size of booster
.
Overload (peak) at xxx  msecs. Check stack.
1. Component failure in the stack. 2. Improper stack assembly
.
3. Incorrect 
Advanced Hardware settings.
1. Check functionality of stack components. 2. Disassemble and reassemble stack. 3. Check the generator's 
Advanced Hardware 
settings.
Over temperature fault!
Generator's internal temperature ex
-
ceeds 158º F (70º Celsius).
1. W
elder duty cycle is too large.
2. W
eld/hold times or forces are too 
large. 3. 
Thruster fan not working.
4. Servo actuator or amplifier is dam
-
aged.
1. Reduce cycle rate. 2. Change setup to reduce weld/hold forces or  decrease weld duration. 3. Check if fan is obstructed; contact DUKANE  service for replacement. 4. Contact DUKANE service.
Overload (frequency) at  xxx msecs. Check stack,  cable or validate ramp up  time.
Generator is unable to lock to the reso
-
nant frequency of the ultrasonic stack.
1. Improper stack assembly
.
2. Defective ultrasound cable. 3. Ramp up time is too short.
1. Disassemble and reassemble stack. 2. Replace ultrasound cable. 3. Increase ramp up time.
Overload (frequency) at  xxx msecs. Check for  coupling between stack  and part.
Generator correctly locks to the resonant  frequency of the ultrasonic stack, but  loses the lock at a point later in the weld  cycle.
Horn comes in contact with the part nest  or anvil.
Make adjustments to thruster and part nest.
Power fault. Check 
AC line.
AC line voltage drops below 190 V
AC on 
240 V
AC systems, and below 95 V
AC on 
120 V
AC systems.
Fluctuations in 
AC power
.
Check the incoming 
AC line power
.