Ethernet Input/Output Module 
Crestron CEN-IO
 
Expand the Ethernet folder and double click on the CEN-IO for a detail view 
(alternatively CTRL+D or drag and drop into Detail View). Assign the signal as 
shown after this paragraph.  
Detail View of the CEN-IO in SIMPL Windows’ Programming Manager 
 
All logic symbols necessary for the SIMPL Windows program must be added from 
the Symbol Library in the Programming Manager workspace. In this example, drag 
and drop two Analog Initialize symbols from the Analog Operations folder, a 
Multiple One Shot symbol from the Timers folder, and two Analog Compare and 
two OR symbols from the Conditional folder into the Logic folder in Program View
Expand the Logic folder and double click on symbol icons for a detail view 
(alternatively CTRL+D or drag and drop into Detail View). Assign signals as shown 
below and on the next page.  
18  
  Ethernet Input/Output Module: CEN-IO 
Operations Guide - DOC. 5718