FIG. 5B – DYNAMIC BRAKE CIRCUIT (Using Inhibit™)
Notes (Dynamic Brake Circuit)
* Choose RB resistance and wattage according to
braking requirements.
** Inhibit™ circuit extinguishes output of control during
brake.  When the armature is reenergized, the Inhibit™
releases which allows for a smooth start.
C. Overload Protection with KBAP-240D (P/N 9106) (Optional)
The KBAP-240D is a multipurpose DC Current Sensing Relay and Overload Protector.  It is specifically designed for
use with DC motors and speed controls from 1/8 - 3 HP.  KBAP-240D operates by sensing current in the armature
circuit.  When the preset level is reached, the output relay (RY1) trips.  An adjustable time delay (0.2 - 15 secs.) is
incorporated, which eliminates nuisance tripping.  Manual or automatic reset is provided at the user's option along
with a LED, which indicates when the preset current level has been reached.  When an overload occurs, the KBAP-
240D can be used to shut the system down, sound an alarm, or initiate corrective action before damage occurs.
Internal Sensing.  Wire the KBAP in accordance with the following wiring diagram.
13
 V. – LIMITED WARRANTY - KBIC
®
For a period of 18 months from date of original purchase, KB will repair or replace without charge devices which our
examination proves to be defective in material or workmanship.  This warranty is valid if the unit has not been
tampered with by unauthorized persons, misused, abused, or improperly installed and has been used in accordance
with the instructions and/or ratings supplied.  The foregoing is in lieu of any other warranty or guarantee, expressed
or implied, and we are not responsible for any expense, including installation and removal, inconvenience, or
consequential damage, including injury to any person, caused by items of our manufacture or sale.  Some states do
not allow certain exclusions or limitations found in this warranty so that they may not apply to you.  In any event, KB's
total liability, under all circumstances, shall not exceed the full purchase price of this unit.  (rev 4/88)
The information contained in this brochure is intended to be accurate.  However, the manufacturer retains the right to make changes in design
which may not be included herein.
KB ELECTRONICS, Inc.
12095 NW 39th Street, Coral Springs, FL  33065 • (954) 346-4900 • Fax (954) 346-3377
Outside Florida Call TOLL FREE (800) 221-6570
A40202