Справочник Пользователя для Garmin 400w series

Скачать
Страница из 24
4
SECTION 2:  L-3 STORMSCOPE INTERFACE
L-3 STORMSCOPE Description
 
NOTE: Refer to the WX-500 Pilot’s Guide for a detailed 
description of the WX-500 STORMSCOPE. 
The L-3 STORMSCOPE WX-500 Weather Map-
ping Sensor is a passive weather avoidance system
that detects electrical discharges associated with
thunderstorms within a 200-NM radius of the aircraft.
The STORMSCOPE measures relative bearing and
distance of thunderstorm-related electrical activity and
reports the information to the display. Interfaces are 
currently only available for the WX-500 STORM-
SCOPE System
.
The 400W/500W Series units perform a self-
test during power-up to ensure proper opera-
tion of the applicable interface components. 
Power-Up Self-Test 
The power-up self-test ensures that the WX-500
functions are operating properly. An error message
is displayed on the Message Page if data is no longer
being received.
User-Initiated Test
In addition to the power-up test, the WX-500 per-
forms a continuous self-test. This continuous self-test
is performed several times per minute. A user-initiated
test can also be performed. The WX-500 Pilot’s Guide
lists all of the possible faults, probable causes, and
recommended actions if system failures are noted.
In addition to the power-up test, the user can 
perform a self-test that is executed through 
the 400W/500W Series unit display. 
To perform a user-initiated test: 
1.  From  the  default  Nav  Page,  turn  the  small 
right  knob  to  select  the  Lightning  (LTNG) 
Page. 
2.  Press MENU to display the Page Menu. 
3.  Turn  the  small  right  knob  to  select “Self-
Test?” and press ENT
190-00356-31  Rev. C
Section 2
L-3 Stormscope Interface