Справочник Пользователя для RoyalTek rdr-3100

Скачать
Страница из 24
 
RoyalTek Confidential
 
20 
RDR-3100 User Manual 
 
8.3 CAN bus (UART B) protocol 
The RDR-3100 provides a second port to receive the speed and reverse message from 
the input source. If the module receives the following input message then the DR 
module will stop reading the speed and reverse message from MCU.  
The communication settings: 
                Baud rate: 38400, n, 8, 1 
                Update rate: 1 Hz 
8.3.1 Speed, Reverse status input Message 
           This sentence contains the speed and reverse information that read from CAN 
bus. The protocol is illustrated as the following: 
Item 
Field 
Description 
Beginning of the sentence 
PSRF121 
Message Header 
Speed 
 
Reverse 
High-normal / Low - activated 
*CC<CR><LF> 
 
 
Example: 
 
Example: 
$PSRF121, 100, 1*25 
Speed = 100 * scaled meter/second 
Reverse isn’t activated 
Checksum = 25 
 
 
 