Справочник Пользователя для Honeywell easy-to-see t87n

Скачать
Страница из 16
T87N/T87K • Owner's Manual
Fan operation settings:
F: For gas or oil heating systems, leave 
the fan operation switch in this factory-set 
position (for systems that control the fan in 
a call for heat).
E: Change the switch to this setting for heat 
pump or electric heat systems. (This setting 
is for systems that allow the thermostat 
to control the fan in a call for heat, if a fan 
wire is connected to the G terminal.)
Align the slots on the base with tabs on the  
thermostat, then push gently until the  
thermostat snaps into place.
Fan operation settings (T87N)
Thermostat mounting
Thermostat
Base
Heating System 
Switch 1  Switch 2
Steam or gravity (1 CPH) 
On 
On
High efficiency warm air 
Off 
On 
(90%+), hot water, or  
heat pump (3 CPH)
Gas or oil warm air 
Off 
Off 
(factory setting) (5 CPH)
Electric warm air (9 CPH) 
On 
Off
Move the cycle rate switches 
to the proper setting for your 
system (see table below).
Cycle rate settings