www.desatech.com
113111-01H
4
saFeTy
Continued
10. This fireplace needs fresh air ventilation to 
run properly. This fireplace has an Oxygen 
Depletion  Sensing  (ODS)  safety  shutoff 
system.  The  ODS  shuts  down  the  fire-
place if not enough fresh air is available. 
See Air for Combustion and Ventilation
page 6. If fireplace keeps shutting off, see 
Troubleshooting, page 24.
11. Do not run fireplace
• where flammable liquids or vapors are 
used or stored.
• under dusty conditions.
12. Do not use this fireplace to cook food or 
burn paper or other objects.
13. Do not use fireplace if any part has been 
under water. Immediately call a qualified 
service  technician  to  inspect  the  room 
fireplace  and  to  replace  any  part  of  the 
control system and any gas control which 
has been under water. 
14. Turn  off  and  unplug  fireplace  and  let 
cool  before  servicing.  Only  a  qualified 
service person should service and repair 
fireplace.
15. Operating  fireplace  above  elevations  of 
4,500 feet could cause pilot outage.
16. Do  not  operate  fireplace  if  any  log  is 
broken. Do not operate fireplace if a log 
is chipped (dime-sized or larger).
17. To prevent performance problems, do not 
use propane/LP fuel tank of less than 100 
lbs. capacity (propane/LP only). 
18. Provide adequate clearances around air 
openings.
Figure 1 - Vent-Free Gas Compact 
Fireplace 
Ignitor Button
Screen 
Fireplace
Cabinet
Logs
Control Knob
loCal Codes
Install and use fireplace with care. Follow all 
local  codes. In the absence  of local  codes, 
use  the  latest  edition  of  The  National  Fuel 
Gas Code, ANSI Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269
State of Massachusetts: The installation 
must  be  made  by  a  licensed  plumber  or 
gas  fitter  in  the  Commonwealth  of  Mas-
sachusetts.
Sellers  of  unvented  propane  or  natural 
gas-fired supplemental room heaters shall 
provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
Vent-free  gas  products are  prohibited  for 
bedroom and bathroom installation in the 
Commonwealth of Massachusetts.