Справочник Пользователя для Hubbell euclid 4291

Скачать
Страница из 4
Euclid Lifting Magnet Controllers: Automatic Discharge
Specifications 4291
period, controlled by the Potentiometer (P1) 
assembly,   the   DSM   de-energizes   the   Drop 
Relay.     This   causes   the   Drop   contactor   to 
open and end the reverse current cycle.
The remaining reverse magnet current flows 
through a secondary discharge path from the 
magnet through the normally closed "power 
auxiliary" interlock of 2L, the DVA and back 
to the magnet.
The Euclid magnet controller can be operated 
by a small notched position master switch or 
a maintained contact-type pushbutton station.
The  arrangement  of  the   circuit  components 
allows an operator to drop portions of a load 
with ease.   This is a feature most operators 
will appreciate.  A portion of the load can be 
dropped by merely moving the master switch 
only  the distance necessary to momentarily 
de-energize the "Lift" contactor.  This feature 
is possible because of the permanently con-
nected discharge path and the elimination of 
having to close the "Drop" contactor before 
opening the "Lift" contactor.
FANNING PACKAGE includes Fanning Con-
tactor   and   Fanning   Resistor   for   separate 
mounting   suitably   enclosed   for   NEMA   2   or 
NEMA 3R service.
Fanning   is   the   insertion   of   a   resistor   dis-
charge path in parallel with the DVA to give 
extended magnet discharge time that is acti-
vated by a separate fanning pushbutton.  The 
operator is allowed to control the rate of mag-
net discharge, dropping all or part of the load, 
by activating the fanning control.   Releasing 
the fanning  pushbutton deactivates the  fan-
ning control and returns the magnet controller 
to the lift mode to retain the remaining mag-
net load.
Comparison ChartSchematic Diagram
Schematic Diagram
Symbol
Function
Symbol
Function
DR
DROP RELAY
MOV
SURGE SUPPRESSOR
PI
POTENTIOMETER ASSEMBLY
DVA
DISCHARGE VARISTOR
CFU
CONTROL FUSE
DSM
DISCHARGE SENSOR MODULE
RFU
DROP FUSE
D
DROP CONTACTOR
DI
DIODE
2L
LIFT CONTACTOR
RECT
RECTIFIER, MAGNET DISCHARGE PATH
1L
LIFT CONTACTOR
Page 2 of 4