 WARNING: Damper handle 
will  be  hot  if  heater  has  been 
running.
1.  STOP!  Read  the  safety  information, 
page 20.
2.  Make  sure  equipment  shutoff  valve  is 
fully open.
3.  Set selector switch in the OFF position.
  WARNING:  Burners  will 
come  on  automatically  within 
one  minute  when  the  selector 
switch is in the ON position after 
the pilot is lit.
4.  Press  in  and  turn  control  knob  clock-
wise 
  to  the  OFF  position  (see 
Figure 25).
5.  Wait five (5) minutes to clear out any gas. 
Then  smell  for  gas,  including  near  the 
floor. If you smell gas, STOP! Follow “B” 
in the safety information, page 20. If you 
don’t smell gas, go to the next step.
6.  Press in and turn control knob counter-
clockwise 
  to  the  PILOT  position. 
Press in control knob for five (5) seconds 
(see Figure 25). 
 
Note:  You  may  be  running  this  heater 
for the first time after hooking up to gas 
supply. If so, the control knob may need 
to be pressed in for 30 seconds or more. 
This will allow air to bleed from the gas 
system.
7.  With control knob pressed in, press and 
release ignitor button. This will light pilot. 
The pilot is attached to the front burner. If 
needed, keep pressing ignitor button until 
pilot lights.
Figure 25 - Control Knob and Ignitor 
Button Location (Shown as Supplied, No 
Control Options)
Flame Adjustment Knob
Control 
Knob
Ignitor 
Button
 Selector Switch in OFF Position
OPERATION 
Continued
REMOTE READY MODELS
 
Note: If pilot does not stay lit, contact a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure, page 22.
8.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
• If control knob does not pop out when 
released,  contact  a  qualified  service 
person or gas supplier for repairs.
 
Note:  If  pilot  goes  out,  repeat  steps  4 
through 8.
9.  Slightly push in and turn control knob coun-
terclockwise 
 to the ON position.
10. Wait  one  minute  and  switch  selector 
switch to the ON position to light burners.  
Note:  AUTO  is  only  functional  when 
using  GWMT1  or  GWMS2  optional  ac-
cessories.
11. Set  flame  adjustment  knob  to  any  level 
between HI and LO.
12. To leave pilot lit and shut off burners only: 
turn control knob clockwise 
 to the 
PILOT  position,  or  use  remote  control 
manual OFF button, or set selector switch 
in the OFF position.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
 WARNING: Make sure the se-
lector switch is in the OFF position 
when you are away from home for 
long periods of time. Heater will 
come on automatically with selec-
tor switch in the ON position.
TO TURN OFF GAS 
TO APPLIANCE
1.  Turn control knob clockwise 
 to the 
OFF position.
2a. Set selector switch in the OFF position.
2b. 
If  Using  Optional  Hand-Held  Remote: 
Set 
selector  switch  in  the  OFF  position  to 
prevent draining battery.
3.  Close equipment shutoff valve (see Figure 
17, page 16).