Справочник Пользователя для National Instruments NI PXI-8104

Скачать
Страница из 69
Chapter 2
Installation and Configuration
2-14
ni.com
through the Identify As submenu. Further expanding the PXI System 
branch shows all devices in the system that can be recognized by 
NI-VISA. When your controller and all your chassis are identified, 
the required 
pxisys.ini
 file is complete.
The PXI specification allows many combinations of PXI chassis and 
system modules. To assist system integrators, the manufacturers of 
PXI chassis and system modules must document the capabilities of their 
products. The minimum documentation requirements are contained in 
.ini
 files, which consist of ASCII text. System integrators, configuration 
utilities, and device drivers can use these 
.ini
 files. 
The capability documentation for the chassis is contained in a 
chassis.ini
 file provided by the chassis manufacturer. The information 
in this file is combined with information about the system controller to 
create a single system initialization file called 
pxisys.ini
 (PXI System 
Initialization). The NI PXI-8104 uses MAX to generate the 
pxisys.ini
 
file from the 
chassis.ini
 file.
Device drivers and other utility software read the 
pxisys.ini
 file to 
obtain system information. For detailed information about initialization 
files, refer to the PXI specification at 
www.pxisa.org
.
Upgrading RAM
You can change the amount of installed RAM on the NI PXI-8104 by 
upgrading the SO-DIMM.
To upgrade the RAM, remove the NI PXI-8104 from the PXI chassis. To 
optimize both memory capacity and system performance, use the same size 
and speed memory module in each of the two module slots. The use of 
different size modules in each slot is supported, but system performance 
will be slower than using two matched modules. However, two mismatched 
modules will result in better performance than using a single module.
National Instruments offers the following types of SO-DIMMs for use with 
the NI PXI-8104 controller. 
PC2-5300 512 MB, 64 MB 
× 64, CL 5, 1.18 in. max
(National Instruments part number 779302-512)
PC2-5300 1 GB, 128 MB 
× 64, CL 5, 1.18 in. max
(National Instruments part number 779302-1024)