Справочник Пользователя для Furuno gp-3500

Скачать
Страница из 192
11. MAINTENANCE & TROUBLESHOOTING 
 
11-2 
 
11.2 
Replacement of Fuse 
Use the correct fuse.
Use of a wrong fuse can cause fire or
damage the equipment.
CAUTION
 
The fuse on the power cable protects the system from reverse polarity of the 
ship’s mains and equipment fault. If the fuse blows, find the cause before 
replacing it. Use only a 3 A fuse. Using the wrong fuse will damage the unit and 
void the warranty. 
Name Type 
Code 
No. 
Fuse FGBO-A 
3A 
AC125V  000-549-063 
 
11.3 
Replacement of Battery 
A battery installed on the circuit board inside display unit preserves data when 
the power is turned off. The life of the battery is about three years. When the 
battery voltage is low the battery icon (
) appears on the display. When this 
happens, contact your dealer to request replacement of the battery. 
Name Type  Code 
No. 
BATT (L1) 
CR2450-F2ST2L 
000-144-941 
 
Note: 
Save data into the memory card or internal memory before replacement of 
the battery.