Справочник Пользователя для National Instruments NI PCI-6110

Скачать
Страница из 118
Chapter 3
Hardware Overview
3-10
ni.com
Programmable Function Inputs
The 10 PFIs are connected to the signal routing multiplexer for each timing 
signal, and software can select a PFI as the external source for a given 
timing signal. Any PFI can be used as an input by any timing signal, and 
multiple timing signals can simultaneously use the same PFI. This flexible 
routing scheme reduces the need to change physical connections to the 
I/O connector for different applications. You can also individually enable 
each PFI pin to output a specific internal timing signal. For example, if you 
need the UPDATE* signal as an output on the I/O connector, software can 
turn on the output driver for the PFI5/UPDATE* pin.
Device and RTSI Clocks
Many functions performed by the NI PCI-6110/6111 require a frequency 
timebase to generate the necessary timing signals for controlling A/D 
conversions, DAC updates, or general-purpose signals at the I/O connector.
The NI PCI-6110/6111 can use either its internal 20 MHz timebase or a 
timebase received over the RTSI bus. In addition, if you configure the 
device to use the internal timebase, you can program the device to drive its 
internal timebase over the RTSI bus to another device that is programmed 
to receive this timebase signal. This clock source, whether local or from the 
RTSI bus, is used directly by the device as the primary frequency source. 
The default configuration at startup is to use the internal timebase without 
driving the RTSI bus timebase signal. This timebase is software-selectable.