Справочник Пользователя для National Instruments NI 9265

Скачать
Страница из 26
NI 9265 Operating Instructions and Specifications
6
ni.com
Special Conditions for Hazardous Locations Use in Europe
This equipment has been evaluated as EEx nC IIC T4 equipment 
under DEMKO Certificate No. 03 ATEX 0324020X. Each module 
is marked 
 II 3G and is suitable for use in Zone 2 hazardous 
locations. If you are using the NI 9265 in Gas Group IIC hazardous 
locations or in ambient temperatures of –40 °C
≤ Ta ≤ 70 °C, you 
must use the device in an NI chassis that has been evaluated as 
EEx nC IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
Special Conditions for Marine Applications
Some modules are Lloyd’s Register (LR) Type Approved for 
marine applications. To verify Lloyd’s Register certification, visit 
ni.com/certification
 and search for the LR certificate, or 
look for the Lloyd’s Register mark on the module.
Caution
To meet radio frequency emission requirements 
for marine applications, use shielded cables and install 
the system in a metal enclosure. Suppression ferrites 
must be installed on power supply inputs near power 
entries to modules and controllers. Power supply and 
module cables must be separated on opposite sides of the 
enclosure and must enter and exit through opposing 
enclosure walls.