Справочник Пользователя для Belkin f5d7000ce2

Скачать
Страница из 29
Report No.: RM920221R04A
8
Issued: Mar. 14, 2003
Reference No.: RM920221R04
4 EMISSION 
TEST
4.1  CONDUCTED EMISSION MEASUREMENT
4.1.1  LIMITS OF CONDUCTED EMISSION MEASUREMENT
Class A (dBuV)
Class B (dBuV)
FREQUENCY (MHz)
Quasi-peak
Average
Quasi-peak
Average
0.15 - 0.5
79
66
66 - 56
56 - 46
0.50 - 5.0
73
60
56
46
5.0 - 30.0
73
60
60
50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15
to 0.50 MHz.
(3) All emanations from a class A/B digital device or system, including any network of
conductors and apparatus connected thereto, shall not exceed the level of field
strengths specified above.
4.1.2 TEST INSTRUMENTS
DESCRIPTION & MANUFACTURER MODEL NO.
SERIAL NO.
CALIBRATED UNTIL
ROHDE & SCHWARZ Test Receiver
ESHS30
828109/007
July 03, 2003
ROHDE & SCHWARZ Artificial
Mains Network (for EUT)
ESH3-Z5
839135/006
July 02. 2003
* ROHDE & SCHWARZ
 4-wire ISN
ENY41
838119/028
Nov. 29, 2003
* ROHDE & SCHWARZ
 2-wire ISN
ENY22
837497/016
Nov. 29, 2003
EMCO-L.I.S.N. (for peripheral)
3825/2
9204-1964
July 02, 2003
Software
Cond-V2M1
NA
NA
RF cable (JYEBAO)
5D-FB
Cable-C02.01
July 5, 2003
HP Terminator (For EMCO LISN)
11593A
E1-01-298
Feb. 23, 2004
HP Terminator (For EMCO LISN)
11593A
E1-01-299
Feb. 23, 2004
NOTE:  1. The calibration interval of the above test instruments is 12 months and the    
  calibrations are traceable to NML/ROC and NIST/USA.
        2. “*”: These equipment are used for conducted telecom port test only (if tested).
3. The test was performed in ADT Shielded Room No. 2.
4. The VCCI Site Registration No. is C-240.