6FKHGXOLQJ
$ERXW6FKHGXOLQJ
The system provides one end-user schedule (programmable by master/installer only),
which can control various types of events.
• Each schedule causes a defined event to start and stop (when appropriate) at a
specified time.
• Schedules can be set to automatically repeat at various intervals.
• Schedules can be set for random starting, if desired.
&UHDWLQJ6FKHGXOHV
1.
                   +  [#] + [6] [4]
(Master Code)
Alpha Displays:
 (-7%61)(
6)%(= 83 %61
2.
Enter “01” as the 2-digit schedule number.
Press [∗] to continue.
)28)6 7',)( 23
=59-8
3.
Enter the desired 2-digit event number from the
following list.
00 = clear the scheduled event
01 = turn a programmed output on or off
)28)6 ):)28
(see 
Using Device Commands section for a list of output device numbers used
in your system)
02 = set a user access schedule for one or more users
(see 
Security Codes section for an explanation of access groups)
03 = send a “latch-key” report to a pager if the system is not disarmed by a specified
time; message sent is “777-7777.”
04 = automatically arm the system in STAY mode at a specified time
05 = automatically arm the system in AWAY mode at a specified time
06 = automatically disarm the system at a specified time
07 = Display the word “REMINDER” at a specified time
Press [∗] to continue.
4. For event number “01,” enter the output number
associated with this schedule.
Otherwise, this prompt is skipped.
Press [∗] to continue to the “Start” prompt below.
():-') 291&)6
<<