6. RAID Controller 
 
 
 
SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA 
49 
Viewing Drive Assignments 
The View Drive Assignments <2> option in the Main Menu displays whether drives are assigned to a 
disk arrays or are unassigned. 
Under the “Assignment” column, drives are labeled with their assigned disk array or shown as “Free” if 
unassigned. Such “Free” drives can be used for a future array or used as a spare drive when a drive fails 
in a mirrored array.    Unassigned drives are not accessible by the OS. The menu also displays the data 
transfer mode that relates to speed used by each drive (U5 refers to 100MB/sec transfers, U4 refers to 
66MB/sec transfer, etc…) 
 
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc. 
 
[ View Drive Assignments ] 
Channel:ID    Drive Model               Capacity(MB)      Assignment      Mode
1 : Mas  QUANTUMCR8.4A     8063 
       Array 1       U5 
1 : Sla     QUANTUMCR8.4A     8063          Free         U5 
2 : Mas  QUANTUMCR8.4A     8063 
       Array 1       U5 
 
[ Keys Available ] 
[
↑] Up [↓] Down  [ESC] Exit   Mode (U=UDMA, P=PIO, D=DMA) 
 
Viewing Array 
The Define Array <3> option in the Main Menu displays the define array. 
 
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc. 
 
[Define Array Menu] 
    Array No        RAID Mode          Total Drv          Capacity(MB)        Status 
   Array 1       Stripe            2             16126      
Functional 
   Array 2                ——                      ——                         —                      —— 
   Array 3                ——                      ——                         ——         —— 
   Array 4                ——                      ——                          ——               —— 
 
[ Keys Available ] 
Note: * — Bootable Array 
 
[
↑] Up [↓] Down   [ESC] Exit   [Enter] Select   [Space] Change Boot Drive