Справочник Пользователя для INSTEON 2993-xx2

Скачать
Страница из 10
Page 6 of 10 
2993-xx2 - Rev: 3/11/2014 9:21 AM 9:21:55 AM 
member that is no longer active. 
5)  Move Diagnostic Keypad to other outlets if/as desired. 
 
If beeping is frequent, you may have a device generating noise. Move Diagnostic Keypad around until the beeping 
occurs most frequently and you should be close to the source. Try turning off devices one at a time until noise 
subsides, then install a FilterLinc to isolate network from noise source. 
 
Another means of locating a noise source is to add the DISTANCE test (see below) to a TRAFFIC test. This is 
especially helpful in locating noise sources in smaller and less busy installations. 
DISTANCE Mode 
1)  Plug in Diagnostic Keypad at a test location. 
2)  Tap REPORT and TRAFFIC buttons until their LEDs are off. 
3)  Tap DISTANCE button until its LED is off. 
4)  Link the Diagnostic Keypad as a controller of the unit under test. 
5)  If unit under test should not be turned on and off rapidly, tap UNLINK button. 
6)  Tap DISTANCE button until LED is on. 
Keypad will send fast-on and fast-off commands as quickly as possible. 
Unit beeps upon receipt of acknowledged commands. 
Faster beeping means better communication. 
Four beeps/second indicate responder hearing message directly (0 hops). 
Two beeps/second indicate responder 3 hops away. 
7)  Important: upon test completion, tap DISTANCE button until LED is off. 
8)  If testing the unit under test is complete, UNLINK device. 
LOCK/UNLOCK 
This button allows you to disable (or re-enable) local setup of unit under test. (This feature is in all products shipped 
after March 2012.) LOCK/UNLOCK prevents accidental changes being made to on-level, ramp rates, etc. To 
determine whether local setup is enabled on a device, press and hold its Set button for 5 seconds. If its LED starts 
blinking, local setup is enabled; tap Set button until LED stops blinking. 
 
1)  Link  Diagnostic Keypad  as a controller of the unit under test (device to be locked or 
unlocked). 
Note: You cannot UNLINK a device from Diagnostic Keypad unless it was the last 
device linked before programming lock was enabled. If another device is still linked to 
Diagnostic Keypad, remove the link by using home automation software  (such as 
HouseLinc) or performing a factory on the device. 
 
2)  Tap LOCK/UNLOCK button. 
a.  If LED is on, you have locked/disabled local setup. 
b.  If LED is off, you have unlocked/re-enabled local setup.  
3)  Tap again if device is not in the desired mode. 
4)  If unit testing is complete, UNLINK device. 
 
Note: If you LOCK a unit under test and then link Diagnostic Keypad to another device, Diagnostic Keypad cannot 
UNLOCK the first unit under test. You will need to use software (such as HouseLinc) to UNLOCK it or perform a 
factory reset. 
ON/OFF 
TOGGLE 
BEEP 
REPORT 
TRAFFIC 
DISTANCE 
LOCK/ 
UNLOCK
 
RELINK 
UNLINK 
ON/OFF 
TOGGLE 
BEEP 
REPORT 
TRAFFIC 
DISTANCE 
LOCK/ 
UNLOCK
 
RELINK 
UNLINK