v To automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller
(QAUTORMT) system value.
v To manually connect the AS/400 to a 5494 controller:
connecting AS/400 to a 5494 controller by Ethernet.
– Use the following table to configure the AS/400 to a 5494 controller that is connected by Ethernet.
For more information about configuring the 5494, see these books:
IBM 5494 Remote Control Unit Planning Guide, GA27-3936
IBM 5494 Remote Control Unit User’s Guide, GA27-3852
AS/400
Prompt
AS/400
Parameter
5494
AS/400
Value
5494 Value
Notes
Field
Subfield
Local
adapter
address
ADPTADR
H1
5
-
-
Values specified in the AS/400 line
description (CRTLINTRN command)
and for the 5494 Remote Controller
Unit must match.
LAN remote
adapter
address
ADPTADR
15
-
-
-
Values specified for the AS/400
CRTCTLAPPC command and for
the 5494 Remote Control Unit must
match.
Local
location
name
LCLLOCNAME
H1
1
-
-
Values specified for the AS/400
CRTCTLRWS command and for the
5494 Remote Control Unit must
match. This will probably match
LCLLOCNAME in the network
attributes. This value will probably
match the LCLLOCNAME in the
network attributes.
Remote
control
point name
RMTCPNAME
13
-
-
-
Values specified for the AS/400
CRTCTLAPPC command and for
the 5494 Remote Control Unit must
match.
Remote
network
identifier
RMTNETID
11
3
-
-
Values specified for the AS/400
CRTCTLAPPC and CRTCTLRWS
commands and for the 5494
Remote Control Unit must match.
This will probably match LCLNETID
in the network attributes and H1:2.
Remote
location
name
RMTLOCNAME
12
-
-
-
Values specified for the AS/400
CRTCTLRWS command and for the
5494 Remote Control Unit must
match.
Example: Connecting AS/400 to a 5494 controller connected by Ethernet
Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.
Example: AS/400 to 5494 controller that is connected by Ethernet
The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you
use Ethernet.
Chapter 7. Communicating with remote workstation controllers
45