VENTING INSTallaTION
 WARNING: Read all instruc-
tions completely and thoroughly 
before  attempting  installation. 
Failure to do so could result in 
serious injury, property damage 
or loss of life.
NOTICE: Failure to follow these in-
structions will void the warranty.
NOTICE:  Do  not  seal  vent  cap 
to pipe. Cap must be removable 
for service.
INSTALLATION pRECAUTIONS
•  Wear gloves and safety glasses for protection
•  Use extreme caution when using ladders 
or when on roof tops
•  Be  aware  of  electrical  wiring  locations  in 
walls and ceilings
The  following  actions  will  void  the  warranty 
on your venting system:
•  Installation of any damaged venting com-
ponent
•  Unauthorized modification of the venting sys-
tem (Do not cut or alter vent components)
•  Installation  of  any  component  part  not 
manufactured or approved by FMI PROD-
UCTS, LLC
•  Installation  other  than  as  instructed  by 
these instructions
 WARNING: This gas fireplace 
and vent assembly must be vented 
directly to the outside. The venting 
system must NEVER be attached 
to a chimney serving a separate 
solid fuel burning appliance. Each 
direct-vent gas appliance must use 
a separate vent system. Do not use 
common vent systems.
 
WARNING: Vent pipe air space 
clearances  to  combustibles  are 
1" on all sides except on the hori-
zontal sections, which require 2" 
clearances  from  the  top  of  the 
pipe.  Where  the  termination  cap 
penetrates a combustible wall, 1" 
air space clearance is required.
NOTICE:  Read  these  instruc-
tions completely before attempt-
ing installation.
These  models  are  tested  and  approved  for 
use with FMI PRODUCTS, LLC (direct-vent) 
pipe components and terminations.
The  venting  system  must  terminate  on  the 
outside  of  the  structure  and  can  not  be  at-
tached to a chimney or flue system serving a 
separate solid fuel or gas burning appliance. 
A  direct-vent  appliance  must  have  its  own 
venting system. DO NOT common vent this 
appliance.
These  models  are  approved  to  be  vented 
either horizontally through an outside wall or 
vertically through a roof or chase enclosure 
using the following guidelines:
•  When venting system terminates horizon-
tally  on  an  outside  wall,  you  may  install 
a  standoff  if  the  termination  cap  is  to  be 
installed  directly  on  a  combustible  finish 
such as vinyl, wood, stucco, etc.
•  Never run the vent downward as this may 
cause excessive temperatures which could 
cause a fire.
•  Vent  pipe  air  space  clearances  to  com-
bustibles are 1" on all sides except on the 
horizontal sections, which requires 2" clear-
ance from the top of the pipe. Where the 
termination cap penetrates a combustible 
wall, 1" air space clearance is required.
•  Snorkel  terminations  are  required  when 
minimum  clearance  to  grade  cannot  be 
met (see Figure 16 on page 12).
•  Have fireplace and selected vent compo-
nents on hand to help determine the exact 
measurements when elbowing or offsetting. 
Always use wall firestops when penetrating 
walls and firestops when penetrating ceil-
ings or attic spaces.
•  If  using  a  venting  configuration  of  only 
horizontal  venting  with  no  vertical  run,  a 
1/4"  rise  for  every  12"  of  run  toward  the 
termination is required.
•  For installation of fireplace at elevations of 
4000 feet or greater, pay special attention 
to venting requirement recommendations.