136
170PAX4 Maintenance Manual
57518L-001 Rev. A
3/18/05
Preventive and Corrective Maintenance
Preventive Maintenance—Cleaning the Peel Bar and Media Path
Cleaning the Peel Bar and Media Path
In case of a label jam, the peel bar and peel roller can be accessed for cleaning. 
To clean the peel bar and media path, complete these steps:
1.
Rotate the printhead locking lever clockwise for right-hand print engines, 
counterclockwise for left-hand print engines, and open the printhead to its fully open 
position.
2.
Check the entire media path for stuck labels and adhesive residue.
3.
Remove any stuck labels from the peel bar and remove all adhesive residue.
4.
Brush, blow, or vacuum any accumulated paper lint and dust away from all of the rollers, 
media, and ribbon sensors.
Figure 53 • Side View of Ribbon Sensor Locations
(Right-Hand Model Shown)
5.
Reload ribbon and media.
6.
Close and latch the printhead locking lever. 
7.
Close the front cover.
8.
Restore power, and run the PAUSE Key Self Test to check print quality.
Note • 
Remove media to make the following cleaning procedure easier.
Ribbon 
Sensor
Ribbon Sensor 
Reflector
Printhead