Digital Joystick Camera Controller
Operations Guide – DOC. 6341
Digital Joystick Camera Controller: C2N-CAMIDJ
• 25
3. Select
the
RS-232 connection type. Verify the available COM is
selected. Verify that the baud rate is set to 115200 (PRO2 default), the
parity is None, the data bits is Eight, the stop bits is One, XON/XOFF
is not selected, and RTS/CTS is selected. Click the OK button to save
the settings and close the window.
parity is None, the data bits is Eight, the stop bits is One, XON/XOFF
is not selected, and RTS/CTS is selected. Click the OK button to save
the settings and close the window.
“Port Settings” Window
NOTE: The parameters shown in the illustration above are the port settings for a
2-Series control system. Consult the Operations Guide for the control system being
used for exact parameter selection.
2-Series control system. Consult the Operations Guide for the control system being
used for exact parameter selection.
4. To verify communication, select Diagnostics | Establish
Communications (Find Rack). This should display a window that
gives the COM port and baud rate. If communication cannot be
established, refer to the “Troubleshooting Communications” section in
the latest version of the 2-Series Control System Reference Guide
(Doc. 6256).
gives the COM port and baud rate. If communication cannot be
established, refer to the “Troubleshooting Communications” section in
the latest version of the 2-Series Control System Reference Guide
(Doc. 6256).
Uploading a SIMPL Windows Program
A control system source file has
the extension .smw. A compiled
SIMPL Windows file has the
extension .spz for a 2-Series
control system.
the extension .smw. A compiled
SIMPL Windows file has the
extension .spz for a 2-Series
control system.
The SIMPL Windows file can be uploaded to the control system using SIMPL
Windows or via the Crestron Viewport.
Windows or via the Crestron Viewport.
Upload via SIMPL Windows
1. Start
SIMPL
Windows.
2. Select
File | Open to view the “Open” window, navigate to the SIMPL
Window file (.smw), and click Open.
3. Select
Project | Transfer Program.