both INSTEON and X10 commands
 
My light only turns off 
when I tap the paddle 
top on SwitchLinc, but I 
can brighten and dim it 
You may have removed an 
INSTEON device that your 
SwitchLinc is trying to operate 
SwitchLinc is retrying the 
missing INSTEON device 
If the INSTEON device is still available, unlink it 
from SwitchLinc. See Removing SwitchLinc as 
an INSTEON Controller
Perform a factory reset. See Factory Reset
When I press the paddle 
on SwitchLinc, it takes a 
long time for other 
INSTEON responders to 
respond
 
You may have removed an 
INSTEON device that your 
SwitchLinc is trying to operate. 
SwitchLinc is retrying the 
missing INSTEON device 
 
If the INSTEON device is still available, unlink it 
from SwitchLinc. Se
 SwitchLinc 
Relay as an INSTEON Responder
 
Perform a factory reset. Se
 Reset
 
SwitchLinc doesn't 
respond to X10 address 
A1 when I first set it up
 
Unlike previous X10-only 
products, SwitchLinc does not 
have an X10 address set up at 
the factory
 
Set up an X10 address. See Adding an X10 
Address
 
The load is buzzing 
when on or dim 
The dimming component 
inside SwitchLinc "chops" the 
powerline sine wave to reduce 
the power 
The buld filaments are vibrating. Use rough-
service, 130V or appliance-grade bulbs to 
reduce the noise. 
Run SwitchLinc in “full-on” mode or switch to a 
non-dimming SwitchLinc On/Off Relay. 
SwitchLinc is locked up 
 
A surge or excessive noise on 
the powerline may have 
glitched it
 
Pull the Set button on SwitchLinc all the way 
out to create an air gap, wait 10 seconds, then 
push it back in until it’s flush with the trim frame 
(don't push it all the way in). 
 
If the above doesn't work, perform a factory 
reset. See 
 Reset
 
SwitchLinc is getting 
warm to the touch 
It is normal for wall dimmers to 
feel warm, but not hot 
SwitchLinc Dimmer will dissipate about 1W per 
100W controlled. Using metal wall boxes, 
removing insulation around the box or 
controlling a smaller load can lessen the heat. 
SwitchLinc can turn off 
my responder, but 
nothing happens when I 
send an ON command 
from SwitchLinc
 
Your responder may be linked 
at its off state
 
Relink your responder to SwitchLinc, while the 
responding device is on
 
My controller can turn off 
SwitchLinc, but 
SwitchLinc does not turn 
on when I send an ON 
command from my 
controller
 
SwitchLinc may be linked at its 
off state
 
Relink SwitchLinc to your controller, while the 
load is on
 
After wiring in 
SwitchLinc, the unit lets 
out a continuous beep 
SwitchLinc is issuing an error 
beep because the unit is wired 
incorrectly 
Turn off the circuit breaker and try reinstalling 
SwitchLinc. If you are still experiencing an error 
beep, consult an electrician to help you install 
SwitchLinc. 
SwitchLinc trips the Arc 
Fault Circuit Interrupter 
(AFCI) 
The AFCI might be too 
sensitive 
Replace your AFCI with a less sensitive brand 
or model from a hardware store with a 
customer-friendly return policy. SwitchLinc 
modules do not trip when used with the 
following AFCI models: