2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM 
Adjust Local Settings 
Local On-Level 
The local on-level is the brightness at which the connected load will come on when turned on at the 
switch wired into Micro module. The default on-level is 100% brightness, but it can be set to any one of 32 
fixed brightness levels (3% to 100%) or “resume dim” (brightness prior to last being turned off). 
1)  Press and hold set button until it beeps 
 
 
LED will start blinking green
 
2)  Press and hold set button until it beeps a second time 
 
 
LED will start blinking red
 
3)  Press and hold set button until it beeps a third time 
 
 
LED will start blinking green
 
4)  Press and hold set button until it beeps a fourth time 
 
 
LED will start blinking red 
5)  Tap set button 
 
 
LED will start double-blinking red 
6)  Use Micro module on/off buttons to adjust load to desired brightness 
7)  Press and hold set button until it double-beeps 
LED will stop blinking and turn on green 
8)  Test by turning off and then back on via the paddle 
Light will turn on at new local on-level 
 
Local Ramp Rate 
The local ramp rate is the time it takes for the connected light to reach 100% brightness from full-off. The 
default local ramp rate is 0.5 seconds, but it can be adjusted from instant-on to 5 seconds (using set 
button) or up to 8 minutes (with software). 
Note: If your local on-level is set to a brightness level that is less than 100%, the ramp rate will be faster 
than programmed. For example, if your light has a 50% local on-level and a ramp rate of 2 seconds, it will 
take 1 second for it to ramp from full-off to the local on-level. 
1)  Press and hold set button until it beeps 
 
 
LED will start blinking green
 
2)  Press and hold set button until it beeps a second time 
 
 
LED will start blinking red 
3)  Press and hold set button until it beeps a third time 
 
 
LED will start blinking green 
4)  Press and hold set button until it beeps a fourth time 
 
 
LED will start blinking red 
5)  Slowly tap set button 2 times 
 
 
LED will continue blinking red 
6)  Press and hold set button to see the next selected ramp rate 
Load will ramp from off to on at the next available ramp rate 
LED will continue blinking red
 
7)  If this is the desired ramp rate, tap set button to accept 
Micro module will double beep and LED will stop blinking 
8)  To see the next ramp rate, press and hold set button again 
Load will ramp from off to on at the next available ramp rate